First and Second Law Analysis of a Solar Operated Ejector Absorption Refrigeration System

机译:太阳能喷射式吸收式制冷系统的第一定律和第二定律分析

获取原文
获取原文并翻译 | 示例
       

摘要

This analysis for the first and second law of a solar operated ejector absorption refrigeration system using duratherm 600 oil as the heat transfer fluid is performed. The proposed cycle is an integration of ejector in the absorption refrigeration cycles which could produce refrigeration output with independent of pressure of the condenser so amount of refrigerant vaporized increased. Both exergy destruction and losses in each component and hence in the overall system are determined. The effects of some influenced parameters like; generator temperature and the evaporator temperature have been observed on first and second law performance. Analysis clearly shows that performance evaluation based on first law analysis is inadequate and hence more meaningful evaluation must include second law analysis.