首页> 外文期刊>International journal of oral and maxillofacial surgery >Validation of a novel semi-automated method for three-dimensional surface rendering of condyles using cone beam computed tomography data
【24h】

Validation of a novel semi-automated method for three-dimensional surface rendering of condyles using cone beam computed tomography data

机译:使用锥束计算机断层扫描数据验证con骨三维表面渲染的新型半自动方法

获取原文
获取原文并翻译 | 示例

摘要

Morphological changes of the condyles are often observed following orthognathic surgery. In addition to clinical assessment, radiographic evaluation of the condyles is required to distinguish the physiological condylar remodelling from pathological condylar resorption. The low contrast resolution and distortion of greyscale values in cone beam computed tomography (CBCT) scans have impeded an accurate three-dimensional (3D) rendering of the condyles. The current study proposes a novel semi-automated method for 3D rendering of condyles using CBCT datasets, and provides a clinical validation of this method. Ten patients were scanned using a standard CBCT scanning protocol. After defining the volume of interest, a greyscale cut-off value was selected to allow an automatic reconstruction of the condylar outline. The condylar contour was further enhanced manually by two independent observers to correct for the under- and over-contoured voxels. Volumetric measurements and surface distance maps of the condyles were computed. The mean within-observer and between-observer differences in condylar volume were 8.62 mm3 and 6.13 mm3, respectively. The mean discrepancy between intra- and inter-observer distance maps of the condylar surface was 0.22 mm and 0.13 mm, respectively. This novel method provides a reproducible tool for the 3D rendering of condyles, allowing longitudinal follow-up and quantitative analysis of condylar changes following orthognathic surgery.
机译:在正颌外科手术之后,通常会观察到the的形态变化。除临床评估外,还需要对radio进行影像学评估,以区分生理性re突重塑与病理性sorption突吸收。锥束计算机断层扫描(CBCT)扫描中较低的对比度分辨率和灰度值的失真已阻碍了con的精确三维(3D)渲染。当前的研究提出了一种使用CBCT数据集进行con突3D渲染的新型半自动化方法,并提供了对该方法的临床验证。使用标准CBCT扫描方案扫描了十名患者。定义感兴趣的体积后,选择灰度截止值以允许自动重建con突轮廓。 two突轮廓由两个独立的观察者手动进一步增强,以校正轮廓不足和轮廓过高的体素。计算的体积测量值和表面距离图。 con突体积的平均观察者内和观察者间差异分别为8.62 mm3和6.13 mm3。 the突表面的观察者内和观察者间距离图之间的平均差异分别为0.22 mm和0.13 mm。这种新颖的方法为for的3D渲染提供了可重现的工具,可进行正颌手术后的longitudinal骨变化的纵向随访和定量分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号