首页> 外文期刊>International journal of oral and maxillofacial surgery >Measurement of oxygen partial pressure in the mandibular bone using a polarographic fine needle probe.
【24h】

Measurement of oxygen partial pressure in the mandibular bone using a polarographic fine needle probe.

机译:使用极谱极细针探针测量下颌骨中的氧分压。

获取原文
获取原文并翻译 | 示例
           

摘要

In this study, the oxygen partial pressure in the cancellous bone substance of the mandible was measured for the first time with a polarographic fine needle probe. This has so far only been established in soft tissue. The aim was to prove and to test the feasibility in principle of this method of measurement in order to ascertain the normal values for the O2 partial pressure in healthy bone. These values were afterwards compared with the results of measurements in areas of different pathological bone conditions in order to assess the clinical suitability of the method for "mapping" during mandibular resection. Measurements of oxygen partial pressure were made in a total of 42 patients (16 women, 26 men). Of these, 12 patients with clinically normal bones served as a control group. Seventeen patients had osteoradionecrosis following radiation treatment, and 13 patients presented with chronic osteomyelitis of the mandible. All measurements were carried out with a polarographic fine needle probe applied to the cancellous bone substance. The statistical analysis included a comparison of the mean values of the oxygen partial pressures measured. No statistical correlation between oxygen partial pressure and pH and hemoglobin values could be detected. The average oxygen partial pressure in the healthy mandibular bone was 71.4 mmHg. In non-healthy bone, the value fell to an average of 30.6 mmHg (osteoradionecrosis 32.3 mmHg, chronic osteomyelitis of the mandibular bone 28.4 mmHg). Statistically, the differences in the group values ascertained were highly significant (P < 0.005). The data found show that this method can be successfully used to detect poorly perfused bone. The values are reproducible and reflect the clinical situation. In the long term, the method appears to be a suitable diagnostic tool for assessing the oxygen supply in bone in studying various clinical problems related to bone surgery.
机译:在这项研究中,首次使用极谱细针探针测量了下颌骨的松质骨物质中的氧分压。迄今为止,这仅在软组织中得以确立。目的是证明并测试这种测量方法的可行性,以便确定健康骨骼中O2分压的正常值。然后将这些值与在不同病理性骨状况区域中的测量结果进行比较,以评估下颌骨切除术中“映射”方法的临床适用性。总共对42位患者(16位女性,26位男性)进行了氧分压的测量。其中,有12例临床上骨骼正常的患者作为对照组。放射治疗后有17例骨放射性坏死,而下颌骨慢性骨髓炎为13例。所有的测量均使用极细微针探针应用于松质骨质。统计分析包括对测得的氧气分压平均值的比较。氧分压与pH和血红蛋白值之间没有统计相关性。健康的下颌骨中的平均氧分压为71.4 mmHg。在不健康的骨骼中,该值下降到平均30.6 mmHg(骨放射性坏死32.3 mmHg,下颌骨慢性骨髓炎28.4 mmHg)。从统计学上讲,确定的组值差异非常显着(P <0.005)。发现的数据表明该方法可以成功地用于检测灌注不良的骨骼。这些值是可复制的,反映了临床情况。从长远来看,该方法似乎是用于评估与骨骼手术有关的各种临床问题的骨中氧供应的诊断工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号