首页> 外文期刊>British Journal of Radiology >Reference dose levels for patients undergoing common diagnostic X-ray examinations in Irish hospitals.
【24h】

Reference dose levels for patients undergoing common diagnostic X-ray examinations in Irish hospitals.

机译:在爱尔兰医院接受常规X射线检查的患者的参考剂量水平。

获取原文
获取原文并翻译 | 示例

摘要

Wide variations in patient dose for the same type of X-ray examination have been evident from various international dose surveys. Reference dose levels provide a framework to reduce this variability and aid in the optimization of radiation protection. The aim of this study was to establish, for the first time, a baseline for national reference dose levels in Ireland for four of the most common X-ray examinations: chest, abdomen, pelvis and lumbar spine. Measurements of entrance surface dose using thermoluminescent dosemeters (TLDs) for these four X-ray examinations were performed on 10 patients in each of 16 randomly selected hospitals. This represented 42% of Irish hospitals applicable to this study. Results have shown wide variation of mean hospital doses, from a factor of 3 for an anteroposterior lumbar spine to a factor of 23 for the chest X-ray. The difference between maximum and minimum individual patient dose values varied up to a factor of 75. Reasons for these dose variations were complex but, in general, low tube potential, high mAs and low filtration were associated with high-dose hospitals. This study also demonstrated lower reference dose levels of up to 40% when compared with those established by the UK and the Commission of the European Communities for four out of six projections. Only the chest X-ray exhibited a similar reference level to those established elsewhere. This emphasizes the importance of each country establishing its own reference dose levels that are appropriate to their own radiographic techniques and practices in order to optimize patient protection.
机译:从各种国际剂量调查中可以明显看出,对于同一类型的X射线检查,患者剂量存在很大差异。参考剂量水平提供了减少这种变异性的框架,并有助于优化辐射防护。这项研究的目的是首次为爱尔兰最常见的四种X射线检查:胸部,腹部,骨盆和腰椎检查建立国家参考剂量水平的基线。在16家随机选择的医院中的每家医院的10名患者中,使用热发光剂量计(TLD)对这四次X射线检查进行了入口表面剂量测量。这占适用于本研究的爱尔兰医院的42%。结果表明,平均医院剂量的差异很大,从前后腰椎的3倍到胸部X线的23倍。最大和最小个体患者剂量值之间的差异高达75倍。造成这些剂量变化的原因很复杂,但总的来说,高剂量医院与管电势低,mAs高和滤过低有关。这项研究还表明,与英国和欧洲共同体委员会确定的六项预测中的四项相比,参考剂量水平降低了40%。只有胸部X光表现出与其他地方相似的参考水平。这强调了每个国家建立自己的参考剂量水平以适合其自身的放射照相技术和实践以优化患者保护的重要性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号