We report the development and testing of a collector arrangement for quadrupole inductively coupled plasma mass spectrometry (ICP-MS) that for the first time has been used to isolate small quantities of highly enriched (>99.99%) single isotopes, with deposition rates >10 ng h(-1). The collector assembly replaces the standard instrument detector allowing for implantation with simultaneous monitoring of the incident ion current. Even under zero bias implant conditions, low energy (<10 eV) ion, collection efficiency was observed to be very high 99%. Eu-151 ion currents of 0.1-0.5 nA were collected on a simple, planar foil without resorting to any type of cup configuration. Recovery of the enriched isotope from such foils is much simpler than from a more complex cup configuration. High rejection of adjacent mass isotopes was demonstrated by selectively implanting Er-167, then using laser ablation ICP-MS imaging to confirm the absence of any co-implanted Er-166 or Er-168. The important analytical possibilities of this new approach to isotope ratio measurement, tracer purification, and radiation measurements are discussed. (C) 2014 Elsevier B.V. All rights reserved.
机译:我们报道了四极杆电感耦合等离子体质谱仪(ICP-MS)的收集器装置的开发和测试,该装置首次用于分离少量的高浓缩(> 99.99%)单一同位素,沉积速率> 10 ng h(-1)。收集器组件取代了标准的仪器检测器,可进行植入并同时监视入射离子电流。即使在零偏压注入条件下,低能量(<10 eV)离子,也观察到非常高的收集效率,达到99%。在简单的平面箔片上收集到0.1-0.5 nA的Eu-151离子电流,而无需采用任何类型的杯状配置。从这样的箔中回收富集的同位素比从更复杂的杯状结构中回收要容易得多。通过选择性注入Er-167,然后使用激光烧蚀ICP-MS成像确认不存在任何共注入的Er-166或Er-168,证明了对邻近质量同位素的高排斥。讨论了这种新方法在同位素比测量,示踪剂纯化和辐射测量中的重要分析可能性。 (C)2014 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号