A series of experiments has been conducted to investigate the effect of wavy interface on film condensation with and without a noncondensable gas present on a vertical wall. Concurrently, the instantaneous film thickness was measured. Overall heat transfer coefficients across the condensate film and the diffusion layer formed by a noncondensable gas were obtained in various parameters such as air-mass fraction (W = 0.1–0.7), mixture vapor velocity (Uin = 3, 5, 7 m/s) and condensate film Reynolds number (Reff,in= 0–19,000). In order to investigate the heat transfer enhancement induced by a dynamic interaction of the surface waves on condensate and the diffusion layer, vapor-side heat transfer coefficient was estimated from the measured overall heat transfer coefficient and the correlation of film-side heat transfer coefficient, and compared with that estimated by Colburn and Chilton-Colburn analogy for a smooth flat plate. The comparison showed that the vapor-side heat transfer coefficient increased clearly with the increase of film Reynolds number. The enhancement effect was dominant for low mixture vapor velocity and decreased with the increase of mixture vapor velocity.
机译:已经进行了一系列实验,以研究波浪形界面对垂直壁上有无不凝性气体存在时薄膜凝结的影响。同时,测量瞬时膜厚度。在各种参数(例如空气质量分数(W = 0.1-0.7),混合蒸气速度(Uin = 3、5、5、7 m / s)等条件下,获得了由不凝性气体形成的整个冷凝膜和扩散层的总传热系数。 )和冷凝膜雷诺数(Reff,in = 0–19,000)。为了研究凝结水和扩散层上表面波的动态相互作用引起的传热增强,根据测得的总传热系数和薄膜侧传热系数的相关性,估算了蒸气侧传热系数,并与Colburn和Chilton-Colburn类比得出的光滑平板的估计值进行比较。比较表明,随着薄膜雷诺数的增加,蒸汽侧传热系数明显增加。增强作用在低混合蒸气速度下是主要的,并且随着混合蒸气速度的增加而减小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号