Calibration of volumetric proving tanks can be done using different methods. For the calibration of large proving tanks the master meter method can be used as a good alternative to the volumetric transfer method or the gravimetric method. When the master meter method is used in most cases a positive displacement meter is used. A better option is to make use a Coriolis mass flow meter as the master meter. Test data is presented of a calibration of a proving tank with a nominal volume of 500 L. Small repeatability figures can be obtained of consecutive calibration runs with a Coriolis mass flow meter. Also the linearity of the meter factor curve of the Coriolis mass flow meter makes this a better option for the master meter method.
机译:容积验证罐的校准可以使用不同的方法进行。为了校准大型发酵罐,可以使用主仪表法代替体积传递法或重量法。在大多数情况下,当使用主仪表方法时,将使用正位移仪表。更好的选择是使用科里奥利质量流量计作为主仪表。给出了标称容量为500 L的发酵罐校准的测试数据。使用科里奥利质量流量计进行的连续校准运行可以获得小的可重复性数字。而且,科里奥利质量流量计的流量计因子曲线的线性度使其成为主流量计方法的更好选择。