首页> 外文期刊>British Journal of Radiology >Initial experiences of using an automated volumetric measure of breast density: the standard mammogram form.
【24h】

Initial experiences of using an automated volumetric measure of breast density: the standard mammogram form.

机译:使用自动体积测量乳房密度的初步经验:标准的乳房X线照片形式。

获取原文
获取原文并翻译 | 示例
           

摘要

Limitations of area based measures of breast density have led several research groups to develop volumetric measures of breast density, for use in predicting risk and in epidemiological research. In this paper, we describe our initial experiences using an automated algorithm (standard mammogram form, SMF) to estimate the volume of the breast that is dense from digitized film mammograms. We performed analyses on 3816 mammograms of 626 women, who were part of the Glasgow Alumni Cohort and had mammograms taken within the Scottish Breast Screening Programme between 1989 and 2002. Absolute volume of dense breast tissue (SMF volume) and the percentage of the volume of the breast that is dense (SMF%) were calculated. The median (interquartile range) of SMF volume was 66 cm3 (48 to 98), and of SMF% was 23.4% (18.6 to 29.7). SMF%, but not SMF volume, was positively related to a six category classification (SCC) of visually assigned area-based breast density (increase in ln(SMF%) per category increase in SCC: 0.04% (95% CI: 0.03-0.05). The SMF algorithm produced lower SMF volume for craniocaudal (CC) compared with mediolateral oblique (MLO) views, but CC/MLO differences for SMF% were small. The mean right/left difference for ln(SMF volume) was -0.027 cm3 (95% confidence interval (CI) -0.044 to -0.009) and of ln(SMF%) was 0.005% (95% CI -0.008% to 0.019%). We present these initial data as a background for future analytical work using SMF.
机译:基于面积的乳房密度测量方法的局限性导致几个研究小组开发了乳房密度的体积测量方法,以用于预测风险和进行流行病学研究。在本文中,我们描述了使用自动算法(标准的乳房X线照片形式,SMF)来估计我们的初步经验,该乳房从数字化的胶片X线照片中估计了乳房的体积。我们对626名妇女的3816例乳房X线照片进行了分析,这些妇女是格拉斯哥校友队列的一部分,并在1989年至2002年之间在苏格兰乳腺筛查计划中进行了乳房X线照片。致密乳房组织的绝对体积(SMF体积)和计算出致密的乳房(SMF%)。 SMF体积的中位数(四分位数范围)为66 cm3(48至98),SMF%为23.4%(18.6至29.7)。 SMF%,而不是SMF体积,与基于视觉分配的基于区域的乳房密度的六类分类(SCC)呈正相关(每类SCC的ln(SMF%)升高,SCC增加:0.04%(95%CI:0.03-) 0.05)。SMF算法产生的颅尾(CC)的SMF量比中外侧斜(MLO)的低,但SMF%的CC / MLO差异很小,ln(SMF量)的平均左右差为-0.027 cm3(95%置信区间(CI)-0.044至-0.009)和ln(SMF%)为0.005%(95%CI -0.008%至0.019%)。我们将这些初始数据作为背景分析,供将来使用SMF。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号