首页> 外文期刊>British Journal of Radiology >Reduction of radiation dose to patients undergoing barium enema by dose audit.
【24h】

Reduction of radiation dose to patients undergoing barium enema by dose audit.

机译:通过剂量审核减少对钡灌肠患者的放射剂量。

获取原文
获取原文并翻译 | 示例
           

摘要

Nowadays, new fluoroscopic machines are usually equipped with a dose-area product (DAP) meter for dose measurement. In our hospital, DAP meters have been used in the Diagnostic Radiology Department for dose audit since June 1997. Demographic patient data, name of radiologist, fluoroscopic duration and DAP readings of every case were recorded by radiographers. In early 1999, questionnaires were distributed to radiologists who had performed fluoroscopic examinations during the auditing period. 23 radiologists with varying years of experience completed the questionnaire and their practice was analysed. Since familiarization with the examination technique would affect radiologists' practice, these radiologists were divided into two groups for analysis. Radiologists with less than 3 years of experience were grouped together as junior radiologists, whilst others were grouped as senior radiologists. Results of the questionnaire indicated that radiologists generally found DAP meters useful for dose evaluation in the process of technique refinement. Radiologists aware of being under continuous surveillance of their practice showed significant reduction of doses (junior radiologists 25%, pX0.005; senior radiologists 36%, p<0.05) and fluoroscopic times (junior radiologists 36%, p<0.001; senior radiologists 18%, p<0.05) compared with radiologists who were unaware that they were under surveillance but with similar radiological experience. This effect is believed to be because of increased awareness of radiation dose through audit. In addition, this "audit effect" may also affect junior radiologists in decision-making regarding the number of radiographs (p<0.05), but no effect was found for senior radiologists (p>0.5).
机译:如今,新的荧光检查仪通常配备有剂量面积乘积(DAP)仪,用于剂量测量。自1997年6月起,在我们的医院中,放射线诊断仪已使用DAP仪进行剂量审核。放射线照相师记录了每个患者的人口统计学数据,放射线医生的姓名,透视时间和DAP读数。在1999年初,向在审核期间进行了透视检查的放射科医生分发了调查表。 23名具有不同经验的放射科医生完成了调查表,并对他们的实践进行了分析。由于熟悉检查技术会影响放射科医生的实践,因此将这些放射科医生分为两组进行分析。经验不足3年的放射线医师被归为初级放射线医师,其他人则被归类为高级放射线医师。调查表的结果表明,放射科医生通常发现DAP测量仪可用于技术改进过程中的剂量评估。放射科医生意识到正在对其操作进行持续监控,显示剂量(初级放射科医生25%,pX0.005;高级放射科医生36%,p <0.05)和荧光检查时间(初级放射科医生36%,p <0.001)显着降低;高级放射科医生18 %,p <0.05)与不知道自己正在接受监视但具有相似放射经验的放射科医生相比。认为该效果是由于通过审核增加了对辐射剂量的认识。此外,这种“听觉效应”也可能影响初级放射线医师在放射照片数量方面的决策(p <0.05),但对高级放射线医师没有影响(p> 0.5)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号