首页> 外文期刊>British journal of ophthalmology >Influence of the pupil size on visual quality and spherical aberration after implantation of the Tecnis 1-piece intraocular lens.
【24h】

Influence of the pupil size on visual quality and spherical aberration after implantation of the Tecnis 1-piece intraocular lens.

机译:植入Tecnis 1件人工晶状体后,瞳孔大小对视觉质量和球差的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To evaluate the influence of the pupil size on clinical results and objective parameters of optical quality of the Tecnis 1-piece (ZCB00) intraocular lens. SETTING: Centre of Ophthalmology, Eberhard-Karls University Tubingen, Germany. METHODS: In this study 51 eyes were implanted with a Tecnis 1-piece IOL. Best corrected visual acuity (BCVA) and uncorrected visual acuity (UCVA) were assessed postoperatively. Total spherical aberration and corneal spherical aberration for optical zones of 3, 4, 5 and 6 mm were measured. Contrast sensitivity and depth of focus were evaluated with a 3 mm and 5 mm pinhole (PH). RESULTS: The mean follow-up time was 3.0 +/- 0.4 months. Mean UCVA and BCVA were 20/25 +/- 8 letters and 20/18 +/- 4 letters, respectively. BCVA with both a 3 and a 5 mm PH was 20/18 +/- 4 letters. The corneal spherical aberration was 0.02 +/- 0.01, 0.06 +/- 0.03, 0.14 +/- 0.09 and 0.27 +/- 0.22 for 3, 4, 5 and 6 mm optical zones. Mean total spherical aberration was -0.01 +/- 0.02, 0.0 +/- 0.03, 0.0 +/- 0.06 and 0.0 +/- 0.08 mum for 3, 4, 5 and 6 mm optical zones, respectively. Contrast sensitivity was not statistically significant different with a 5 mm or 3 mm PH. In addition, the defocus curves with a 3 mm and a 5 mm PH were not statistically significant different. CONCLUSION: The aspheric profile of the Tecnis 1-piece IOL reduces total spherical aberration to virtually zero at all pupil sizes from 3-6 mm. Thus, visual acuity, contrast sensitivity, refraction and defocus curve show the same good results at large pupil sizes compared with small pupil sizes.
机译:目的:评估瞳孔大小对Tecnis 1片(ZCB00)人工晶状体的临床结果和光学质量的客观参数的影响。地点:德国图宾根埃伯哈德·卡尔斯大学眼科中心。方法:在这项研究中,将51只眼睛植入Tecnis 1件IOL。术后评估最佳矫正视力(BCVA)和未矫正视力(UCVA)。测量了3、4、5和6 mm光学区域的总球差和角​​膜球差。使用3毫米和5毫米针孔(PH)评估对比灵敏度和聚焦深度。结果:平均随访时间为3.0 +/- 0.4个月。平均UCVA和BCVA分别为20/25 +/- 8个字母和20/18 +/- 4个字母。 PH值为3毫米和5毫米的BCVA为20/18 +/- 4个字母。对于3、4、5和6mm光学区域,角膜球差为0.02 +/- 0.01、0.06 +/- 0.03、0.14 +/- 0.09和0.27 +/- 0.22。 3、4、5和6 mm光学区域的平均总球差分别为-0.01 +/- 0.02、0.0 +/- 0.03、0.0 +/- 0.06和0.0 +/- 0.08微米。 PH值为5 mm或3 mm时,对比灵敏度在统计学上无显着差异。此外,PH为3 mm和5 mm的散焦曲线在统计上没有显着差异。结论:Tecnis 1件IOL的非球面轮廓可在3-6 mm的所有瞳孔尺寸下将总球差降低到几乎为零。因此,与小瞳孔尺寸相比,在大瞳孔尺寸下,视敏度,对比敏感度,折射和散焦曲线显示出相同的良好结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号