Understanding the effect of medical gloves on manual performance is critical for improving glove design and mitigating the impediment to surgical performance caused by gloves. Existing test methods do not correspond well with clinical and surgical tasks. Based on interviews with clinicians, two new tests were proposed: locating a pulse in a simulated blood vessel, and placing and tying sutures in simulated tissue. A pilot study was carried out using 19 clinicians employed at Sheffield Teaching Hospitals. Subjects performed each test three times, with latex and nitrile examination gloves, and without gloves, the order being randomised. In addition to objective test scores, subjects' perception of their relative performance in each condition was recorded. In the Pulse Location Test, performance was found to be significantly better without gloves, while differences between gloves were not statistically significant. Perceived performance correlated well with measured performance. In the Suturing Test, no statistically significant performance differences were found between the three hand conditions, although subjects perceived ungloved performance to be significantly better than with either the latex or nitrile gloves. The Pulse Location Test showed promise as a clinical performance evaluation tool, and could be used to improve medical glove design for better tactile performance. The discrepancy between subjects' perceived and measured performance in the Suturing Test needs further investigation to determine whether the perceived differences translate into genuine clinical performance differences that were not able to be measured using the current method, or whether the difference is purely psychological.
机译:了解医用手套对手动操作的影响对于改善手套设计和减轻由手套引起的手术性能的障碍至关重要。现有的测试方法与临床和手术任务不太吻合。根据对临床医生的采访,提出了两项​​新的测试:在模拟血管中定位脉搏,以及在模拟组织中放置和绑扎缝合线。在谢菲尔德教学医院聘用的19位临床医生进行了一项初步研究。受试者用乳胶和丁腈检查手套(不戴手套)进行了三次测试,顺序是随机的。除了客观的测试分数,还记录了受试者在每种情况下相对表现的感觉。在“脉冲位置测试”中,发现不戴手套的性能显着提高,而手套之间的差异在统计学上不显着。感知的性能与测得的性能有很好的相关性。在缝合试验中,虽然受试者感觉到无偏爱的表现明显优于乳胶或丁腈手套,但在三种手部状况之间没有发现统计学上显着的表现差异。脉冲位置测试显示出有望作为临床性能评估工具,并可用于改进医用手套的设计以获得更好的触觉性能。缝合测试中受试者的感知表现和测得表现之间的差异需要进一步调查,以确定感知差异是否转化为使用当前方法无法衡量的真实临床表现差异,还是该差异纯粹是心理上的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号