BACKGROUND: Matrix perimetry is a new iteration of frequency-doubling technology (FDT) which uses a smaller target size in the standard achromatic perimetry presentation pattern. AIM: To compare the performance of matrix and Swedish interactive thresholding algorithm (SITA) perimetry in detecting glaucoma diagnosed by structural assessment. DESIGN: Prospective cross-sectional study. METHODS: 76 eyes from 15 healthy subjects and 61 consecutive glaucoma suspects and patients with glaucoma were included. All patients underwent optic nerve head (ONH) photography, SITA and matrix perimetries, and optical coherence tomography (OCT) within a 6-month period. Glaucoma diagnosis was established by either glaucomatous optic neuropathy or OCT by assessing retinal nerve fibre layer (RNFL) thickness. Mean deviation (MD), pattern standard deviation (PSD), glaucoma hemifield test and cluster of abnormal testing locations were recorded from matrix and SITA perimetries. RESULTS: Similar correlations were observed with matrix and SITA perimetry MD and PSD with either cup-to-disc ratio or OCT mean RNFL. The area under the receiver operating characteristic (AROC) curves of MD and PSD for discriminating between healthy and glaucomatous eyes ranged from 0.69 to 0.81 for matrix perimetry and from 0.75 to 0.77 for SITA perimetry. There were no significant differences among any corresponding matrix and SITA perimetry AROCs. CONCLUSIONS: Matrix and SITA perimetries had similar capabilities for distinguishing between healthy and glaucomatous eyes regardless of whether the diagnosis was established by ONH or OCT-RNFL assessment.
机译:背景:矩阵视野仪是倍频技术(FDT)的新迭代,它在标准消色差视野仪呈现模式中使用较小的目标尺寸。目的:比较矩阵和瑞典交互阈值算法(SITA)视野检查技术在通过结构评估诊断出的青光眼中的性能。设计:前瞻性横断面研究。方法:纳入15名健康受试者的76只眼睛和61名连续的青光眼疑似患者和青光眼患者。所有患者均在6个月内接受了视神经乳头(ONH)摄影,SITA和基质视野检查以及光学相干断层扫描(OCT)。青光眼的诊断是通过青光眼性视神经病变或OCT通过评估视网膜神经纤维层(RNFL)厚度来确定的。从矩阵和SITA视野中记录平均偏差(MD),模式标准偏差(PSD),青光眼半场检查和异常检查位置的群集。结果:矩阵和SITA视野测量法MD和PSD与杯盘比或OCT平均RNFL观察到相似的相关性。 MD和PSD的接收器工作特征(AROC)曲线下用于区分健康眼和青光眼的面积(矩阵视野检查)为0.69至0.81,SITA视野检查的范围为0.75至0.77。在任何相应的矩阵和SITA视野AROC之间没有显着差异。结论:无论是通过ONH还是OCT-RNFL评估来确定,Matrix和SITA视野检查都具有区分健康眼和青光眼的相似能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号