首页> 外文期刊>British journal of ophthalmology >Optical quality assessment in normal and forme fruste keratoconus eyes with a double-pass system: A comparison and variability study
【24h】

Optical quality assessment in normal and forme fruste keratoconus eyes with a double-pass system: A comparison and variability study

机译:双通道系统对正常和全角圆锥角膜眼睛的光学质量评估:比较和变异性研究

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose: To comparatively evaluate the image quality in normal and forme fruste keratoconus patients using a double-pass system. Methods: Fourteen normal eyes and 15 eyes with forme fruste keratoconus were included. Corneal tomographic parameters were obtained with optical coherence tomography. Image quality characteristics were determined by an optical quality analysis system (OQAS). Two readings were obtained from each eye. The following parameters were analysed: modulation transfer function cutoff frequency (MTF), Strehl ratio and OQAS values (OV) at contrasts of 100% (OV-100), 20% (OV-20) and 9% (OV-9). Repeatability coefficient (RC), coefficient of variation (CVw) and intraclass correlation coefficient (ICC) were evaluated. Results: There were no significant differences in central corneal thickness, anterior best-fit sphere and posterior best-fit sphere in both groups. There was a significant difference between the mean MTF (p=0.001), Strehl ratio (p<0.001), OV-100 (p=0.001), OV-20 (p<0.001) and OV-9 (p<0.001) values between both groups. The coefficients of variation were 4.10 (MTF) and 13.77 (Strehl ratio) in normal eyes and 14.53 (MTF) and 14.97 (Strehl ratio) in eyes with forme fruste keratoconus. The ICC values were 0.99 and 0.95 for MTF and, 0.80 and 0.91 for Strehl ratio, in normal and forme fruste keratoconus eyes, respectively. The corresponding repeatability values were 3.53 and 6.15 for MTF and, 0.06 and 0.04 for Strehl ratio, respectively. Conclusions: OQAS has the potential to be a useful diagnostic tool in cases with early keratoconus. The repeatability of a double-pass (DP) system was good in normal as well as forme fruste keratoconus eyes.
机译:目的:使用双通道系统比较评估正常和缩孔圆锥角膜患者的图像质量。方法:包括14只正常眼和15只具圆锥体圆锥角膜的眼。通过光学相干断层扫描获得角膜断层扫描参数。图像质量特征由光学质量分析系统(OQAS)确定。从每只眼睛获得两个读数。分析了以下参数:在100%(OV-100),20%(OV-20)和9%(OV-9)的对比度下的调制传递函数截止频率(MTF),斯特列尔比和OQAS值(OV)。评估了重复性系数(RC),变异系数(CVw)和组内相关系数(ICC)。结果:两组的中央角膜厚度,前最适球和后最适球均无显着差异。平均MTF(p = 0.001),斯特列尔比(p <0.001),OV-100(p = 0.001),OV-20(p <0.001)和OV-9(p <0.001)值之间存在显着差异两组之间。正常人圆锥角膜圆锥形眼的变异系数分别为4.10(MTF)和13.77(Strehl比),以及14.53(MTF)和14.97(Strehl比)。在正常和平顶圆锥角膜眼中,MTF的ICC值分别为0.99和0.95,斯特列尔比的ICC值为0.80和0.91。 MTF的相应重复性值分别为3.53和6.15,Strehl比的相应重复性值分别为0.06和0.04。结论:OQAS有可能成为圆锥角膜早期病例的有用诊断工具。在正常情况下和圆锥角膜圆锥形眼中,双通道(DP)系统的重复性都很好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号