首页> 外文期刊>International Journal of Food Microbiology >Control of Pseudomonas aeruginosa and Stenotrophomonas maltophilia contamination of microfiltered water dispensers with peracetic acid and hydrogen peroxide.
【24h】

Control of Pseudomonas aeruginosa and Stenotrophomonas maltophilia contamination of microfiltered water dispensers with peracetic acid and hydrogen peroxide.

机译:用过氧乙酸和过氧化氢控制微滤水分配器中的铜绿假单胞菌和嗜麦芽窄食单胞菌。

获取原文
获取原文并翻译 | 示例
           

摘要

The abilities of peracetic acid and hydrogen peroxide to remove or reduce Pseudomonas aeruginosa and Stenotrophomonas maltophilia in output water from microfiltered water dispensers (MWDs) were investigated. Two MWDs were inoculated with strains of P. aeruginosa and S. maltophilia isolated from water. Dispensers A and B were disinfected with 10% (v/v) peracetic acid (PAA) and 3% (v/v) hydrogen peroxide (HP) respectively. Each dispenser was disinfected three times at monthly intervals with contact times of 10, 30 and 40 min. Water dispensed by the MWDs was collected immediately before and after each treatment and then twice weekly for the remaining period. Once a week a sample of the tap water entering the dispensers was tested. P. aeruginosa and S. maltophilia were enumerated in the 90 samples collected during 6 months. In the output water from the dispensers before the first treatment, the number of the bacteria was 3 to 4 log cfu/100 mL. Treatment with PAA greatly reduced the numbers of P. aeruginosa and S. maltophilia in the dispensed water initially. However, by 2 days after treatment, the numbers increased and remained high. In the case of disinfection with HP for 40 min, P. aeruginosa was not detected in most of the samples (73.7%). Numbers of S. maltophilia decreased with increasing time after treatment
机译:研究了过氧乙酸和过氧化氢去除或减少微滤水分配器(MWD)出水中铜绿假单胞菌和嗜麦芽单胞菌的嗜麦芽能力。用从水中分离的铜绿假单胞菌和嗜麦芽肿链球菌菌株接种两个MWD。分配器A和B分别用10%(v / v)过氧乙酸(PAA)和3%(v / v)过氧化氢(HP)消毒。每个分配器每月间隔10、30和40分钟消毒3次。在每次处理之前和之后立即收集由MWD分配的水,然后在剩余期间每周两次。每周一次测试进入分配器的自来水样品。在6个月内收集的90个样品中,列举了铜绿假单胞菌和嗜麦芽糖链球菌。在第一次处理之前从分配器中排出的水中,细菌数为3至4 log cfu / 100 mL。最初,用PAA处理可大大减少所分配水中铜绿假单胞菌和嗜麦芽糖链球菌的数量。然而,到治疗后2天,该数目增加并保持高水平。在用HP消毒40分钟的情况下,大多数样品(73.7%)未检出铜绿假单胞菌。治疗后随着时间的增长,嗜麦芽链菌的数量减少

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号