This study investigated health risk reduction in a drinking water treatment plant of Nanjing City (China) based on chemical detection of 22 semi-volatile organic compounds (SVOCs) and 24 metallic elements in source water and drinking water during 2009-2011. Chemical analysis showed that 15 SVOCs and 9 metals were present in the water. Health risk assessment revealed that hazard quotient of each pollutant and hazard index (HI) of all the detectable pollutants were below 1.00, indicating that the chemicals posed negligible non-carcinogenic risk to local residents. Benzo(a) pyrene may induce carcinogenic risk since its risk index via both oral and dermal exposure exceeded the safety level (1.00E-6), but other SVOCs induced no carcinogenic risk. Total HI of the SVOCs was 1.08E-3 for the source water and 1.56E-3 for the drinking water, suggesting that the used conventional treatment processes (coagulation/sedimentation, sand filtration and chlorine disinfection) cannot effectively reduce the non-carcinogenic risk. The source water had higher carcinogenic risk than the drinking water, but risk index of the drinking water still exceeded 1.00E-6. This study might serve as a basis for health risk assessment of drinking water and also as a benchmark for the authorities to reduce health risk arising from trace-level hazardous pollutants.
机译:本研究基于化学检测方法,对2009-2011年南京市某饮用水处理厂的健康风险降低进行了检测,该化学检测方法包括源水和饮用水中的22种半挥发性有机化合物(SVOC)和24种金属元素。化学分析表明,水中存在15种SVOC和9种金属。健康风险评估显示,每种污染物的危害系数和所有可检测到的污染物的危害指数(HI)均低于1.00,表明该化学品对当地居民造成的非致癌风险可忽略不计。苯并(a)may可能引起致癌风险,因为其通过口服和皮肤接触的风险指数均超过安全水平(1.00E-6),但其他SVOC均未引起致癌风险。 SVOC的总HI(原水)为1.08E-3,饮用水为1.56E-3,这表明使用的常规处理工艺(混凝/沉淀,砂滤和氯消毒)不能有效降低非致癌风险。原水的致癌风险高于饮用水,但饮用水的风险指数仍超过1.00E-6。这项研究可以作为饮用水健康风险评估的基础,也可以作为主管部门降低由痕量有害污染物引起的健康风险的基准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号