...
首页> 外文期刊>International Journal of Cosmetic Science >In vitro evaluation of sun protection factors of sunscreen agents using a novel UV spectrophotometric technique
【24h】

In vitro evaluation of sun protection factors of sunscreen agents using a novel UV spectrophotometric technique

机译:新型紫外线分光光度法体外评估防晒剂的防晒因子

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A method for the in vitro determination of low-and high-value sun protection factors (SPF) of sunscreens using artificial substrates and a novel pseudo double beam (PDB) mode of operation of a standard double beam UV spectrophotometer is described. The method allows transmittance to be calculated from detector responses of reference and sample beams measured at different gain levels and facilitates the accurate quantification of low levels of electromagnetic radiation transmitted through highly absorbing samples. The spectrophotometer was modified to hold quartz diffusing plates on which a substrate [Transpore~(TM) adhesive tape or human stratum corneum obtained from a skin surface biopsy (SSB)] and the sunscreens to be tested were applied. The PDB mode of operation increased the effective linear range of the detector response of the spectrophotometer by a factor of approximately 20000-fold, enabling the in vitro SPF determination technique to be applied to both high and low SPF value sunscreens. Eight commercial sunscreens with known SPF values ranging from 4 to 77, previously determined by in vivo methods, were tested in vitro using both test substrates and correlations between the in vivo and in vitro values were determined. SPF values determined using the in vitro method correlated well with the known in vivo results (Transpore~(TM) tape, R~2 = 0.611; SSB, R~2 = 0.7928). The in vitro SPF obtained for one of the tested products differed substantially from the cited in vivo SPF value. Independent in vitro and in vivo re-evaluation of the SPF of this product matched the value predicted by the present method much more closely than the originally cited in vivo value. All determined SPFs were ordered correctly in comparison to in vivo ranking and the technique appeared to correctly identify a sunscreen that had a labelled SPF value that was significantly higher than its true SPF.
机译:描述了一种使用人造基质和标准双光束紫外分光光度计的新型伪双光束(PDB)操作模式体外测定防晒霜的低值和高值防晒系数(SPF)的方法。该方法允许根据在不同增益水平下测量的参考光束和样品光束的探测器响应来计算透射率,并有助于对通过高吸收样品传输的电磁辐射的低水平进行准确定量。修改分光光度计以固定石英扩散板,在其上施加基底[从皮肤表面活检(SSB)获得的Transpore TM胶带或人角质层]和要测试的防晒剂。 PDB操作模式将分光光度计的检测器响应的有效线性范围增加了约20000倍,使体外SPF测定技术可应用于高和低SPF值的防晒霜。使用测试底物在体外测试了八种市售防晒霜,这些防晒霜的SPF值已知在4至77之间,之前已通过体内方法进行了测试,并确定了体内和体外值之间的相关性。使用体外方法测定的SPF值与已知的体内结果(TransporeTM胶带,R-2 = 0.611; SSB,R-2 = 0.7928)很好地相关。对于一种被测产品获得的体外SPF与所引用的体内SPF值有很大不同。对该产品的SPF进行独立的体外和体内重新评估,与通过本方法预测的值相比,与最初引用的体内值更接近。与体内排名相比,所有确定的SPF均正确订购,该技术似乎可以正确识别防晒霜,该防晒霜的SPF值明显高于其真实SPF。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号