Quantitative evaluation of fundus autofluorescence imaged 'in vivo' in eyes with retinal disease.

机译:视网膜疾病的眼睛中“体内”成像的眼底自发荧光的定量评估。

获取原文
获取原文并翻译 | 示例
           

摘要

AIM: To describe a new method of evaluating the topographic distribution of fundus autofluorescence in eyes with retinal disease. METHODS: Images of fundus autofluorescence were obtained in five patients and 34 normal volunteers using a confocal scanning laser ophthalmoscope (cSLO). To evaluate the topographic distribution of fundus autofluorescence throughout the posterior pole a rectangular box, 10 x 750 pixels, was used as the area of analysis. The box was placed, horizontally, across the macular region. The intensity of fundus autofluorescence of each pixel within the rectangular box was plotted against its degree of eccentricity. Profiles of fundus autofluorescence from patients were compared with those obtained from the age matched control group and with cSLO images. RESULTS: Profiles of fundus autofluorescence appeared to represent the topographic distribution of fundus autofluorescence throughout the posterior pole appreciated in the cSLO images, and allowed rapid identification and quantification of areas of increased or decreased fundus autofluorescence. CONCLUSIONS: Fundus autofluorescence profiles appear to be useful to study the spatial distribution of fundus autofluorescence in eyes with retinal disease.
机译:目的:描述一种评估视网膜病变眼底眼底自发荧光分布的新方法。方法:使用共聚焦扫描激光检眼镜(cSLO)在5名患者和34名正常志愿者中获得眼底自发荧光图像。为了评估整个后极的眼底自发荧光的地形分布,使用了一个10 x 750像素的矩形框作为分析区域。将盒子水平放置在整个黄斑区域。绘制矩形框内每个像素的眼底自发荧光强度与其偏心度的关系。将患者的眼底自发荧光图与年龄匹配的对照组和cSLO图像进行比较。结果:眼底自发荧光的轮廓似乎代表了在cSLO图像中赞赏的整个后极的眼底自发荧光的地形分布,并允许快速鉴定和定量眼底自发荧光增加或减少的区域。结论:眼底自发荧光谱似乎有助于研究视网膜病变眼中眼底自发荧光的空间分布。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号