The role of F-18-FDG PET/CT in infectious endocarditis: a systematic review and meta-analysis

机译:F-18-FDG PET / CT在感染性心内膜炎中的作用:系统评价和荟萃分析

获取原文
获取原文并翻译 | 示例

摘要

Purpose: To systematically review and conduct a meta-analysis of the available evidence for PET/CT using F-18-fluorodeoxyglucose as tracers in the imaging of infectious endocarditis (IE). Methods: Databases, including PubMed, Embase, and Web of Science, were searched for studies that examined the diagnostic value of F-18-FDG PET/CT for patients with IE. The reference lists following review articles and those of the included articles were checked to complement the electronic searches. The data extraction and methodological quality assessment were completed by two independent reviewers, and the meta-analysis was then conducted using Meta-Disc software, version 1.4. Results: A total of six studies involving 246 patients was included. The results of the meta-analysis indicated that the pooled sensitivity was 61% (95% confidence interval (CI), 52 - 88%), and the pooled specificity was 88% (95% CI, 80 - 93%). The positive likelihood ratio was 3.24 (95% CI, 1.67 - 6.28, p = 0.224), and the negative likelihood ratio was 0.50 (95% CI, 0.32 - 0.77, p = 0.015). The diagnostic odds ratio was 6.98 (95% CI, 2.55 19.10, p = 0.145), the overall area under the curve (AUC) was 0.8230 (SE = 0.1085), and the Q* value was 0.7563 (SE = 0.0979). Conclusions: F-18-FDG PET/CT is currently not sufficient for the diagnosis of IE because of its low sensitivity. However, F-18-FDG PET/CT might be a useful tool for the diagnosis of skin and pocket cardiovascular implantable electronic device (CIED) infections and prosthetic valve endocarditis (PVE).
机译:目的:以传染性心内膜炎(IE)的成像方式,以F-18-氟脱氧葡萄糖为示踪剂,系统地审查和进行PET / CT可用证据的荟萃分析。方法:检索包括PubMed,Embase和Web of Science在内的数据库,以研究F-18-FDG PET / CT对IE患者的诊断价值。以下评论文章中的参考文献清单和所包括文章的参考文献均经过检查以补充电子检索内容。数据提取和方法学质量评估由两名独立的审阅者完成,然后使用Meta-Disc软件1.4版进行荟萃分析。结果:总共包括246名患者的六项研究。荟萃分析的结果表明,合并的敏感性为61%(95%置信区间(CI),52-88%),合并的特异性为88%(95%CI,80-93%)。正似然比为3.24(95%CI,1.67-6.28,p = 0.224),负似然比为0.50(95%CI,0.32-0.77,p = 0.015)。诊断比值比为6.98(95%CI,2.55 19.10,p = 0.145),曲线下总面积(AUC)为0.8230(SE = 0.1085),Q *值为0.7563(SE = 0.0979)。结论:F-18-FDG PET / CT由于其低敏感性,目前不足以诊断IE。但是,F-18-FDG PET / CT可能是诊断皮肤和袖珍心血管可植入电子设备(CIED)感染和人工瓣膜心内膜炎(PVE)的有用工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号