摘要

Pace et al. (1995) [1] recommended an equation used to predict extinction coefficient of a protein. However, no antibody data was included in the development of this equation. The main objective of this study was to therefore investigate how the predicted value of the extinction coefficient is comparable to the experimentally determined extinction coefficient of antibodies measured by the Edelhoch method. We have measured the extinction coefficients (epsilon) of 13 IgG1 monoclonal antibodies (mAbs) in phosphate buffer at pH 7.2. The maximum variability in the experimentally measured extinction coefficient of a given mAb molecule was found to be about 2%. Experimentally determined extinction coefficients of all mAbs were found to be lower than the predicted value, with the maximum difference found to being 4.7%. The highest and lowest values of experimental extinction coefficient among the thirteen IgG1 monoclonal antibodies obtained were 230525.9 M-1 cm(-1) (i.e. 1.55 (mg/ml)(-1) cm(-1)) and 191,411.6 M-1 cm(-1) (i.e. 1.29 (mg/ml)(-1) cm(-1)). A difference of <3% (with respect to mean value) was observed between the experimental and predicted values of the extinction coefficient. A comprehensive analysis and interpretation of the comparison of the predicted and experimentally determined extinction coefficient by the Edelhoch method is discussed in terms of structural characterization and accessible surface area (ASA). (C) 2015 Elsevier B.V. All rights reserved.
机译:佩斯等。 (1995)[1]提出了一种用于预测蛋白质消光系数的方程。但是,该方程式的开发中未包含抗体数据。因此,这项研究的主要目的是研究消光系数的预测值与通过Edelhoch方法测量的实验确定的抗体消光系数如何可比。我们已经测量了pH 7.2的磷酸盐缓冲液中13种IgG1单克隆抗体(mAbs)的消光系数(ε)。发现给定mAb分子在实验测量的消光系数中的最大变异性约为2%。实验确定所有mAb的消光系数均低于预测值,发现最大差为4.7%。获得的13种IgG1单克隆抗体中的实验消光系数的最高和最低值为230525.9 M-1 cm(-1)(即1.55(mg / ml)(-1)cm(-1))和191,411.6 M-1 cm (-1)(即1.29(mg / ml)(-1)cm(-1))。在消光系数的实验值和预测值之间观察到<3%(相对于平均值)的差异。根据结构特征和可及表面积(ASA),讨论了通过Edelhoch方法对预测的和实验确定的消光系数进行比较的综合分析和解释。 (C)2015 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号