New Microfluidic-Based Sampling Procedure for Overcoming the Hematocrit Problem Associated with Dried Blood Spot Analysis

机译:基于微流控的新型采样程序,用于克服与干血斑分析相关的血细胞比容问题

获取原文
获取原文并翻译 | 示例

摘要

Hematocrit (Hct) is one of the most critical issues associated with the bioanalytical methods used for dried blood spot (DBS) sample analysis. Because Hct determines the viscosity of blood, it may affect the spreading of blood onto the filter paper. Hence, accurate quantitative data can only be obtained if the size of the paper filter extracted contains a fixed blood volume. We describe for the first time a microfluidic-based sampling procedure to enable accurate blood volume collection on commercially available DBS cards. The system allows the collection of a controlled volume of blood (e.g., 5 or 10 mu L) within several seconds. Reproducibility of the sampling volume was examined in vivo on capillary blood by quantifying caffeine and paraxanthine on 5 different extracted DBS spots at two different time points and in vitro with a test compound, Mavoglurant, on 10 different spots at two Hct levels. Entire spots were extracted. In addition, the accuracy and precision (n = 3) data for the Mavoglurant quantitation in blood with Hct levels between 26 and 62 were evaluated. The interspot precision data were below 9.0, which was equivalent to that of a manually spotted volume with a pipet. No Hct effect was observed in the quantitative results obtained for Hct levels from 26 to 62. These data indicate that our microfluidic-based sampling procedure is accurate and precise and that the analysis of Mavoglurant is not affected by the Hct values. This provides a simple procedure for DBS sampling with a fixed volume of capillary blood, which could eliminate the recurrent Hct issue linked to DBS sample analysis.
机译:血细胞比容 (Hct) 是与用于干血斑 (DBS) 样品分析的生物分析方法相关的最关键问题之一。由于Hct决定了血液的粘度,因此可能会影响血液在滤纸上的扩散。因此,只有当提取的滤纸的尺寸包含固定的血容量时,才能获得准确的定量数据。我们首次描述了一种基于微流体的采样程序,以便在市售的 DBS 卡上实现准确的血容量采集。该系统允许在几秒钟内收集受控体积的血液(例如,5 或 10 μ L)。通过在两个不同的时间点和 10 个不同点的 10 个不同点上用测试化合物 Mavoglurant 在体外量化 5 个不同提取的 DBS 点上的咖啡因和对黄嘌呤,在毛细血管血液上检查采样体积的可重复性。提取了整个斑点。此外,还评估了 Hct 水平在 26% 至 62% 之间的血液中 Mavoglurant 定量的准确性和精密度 (n = 3) 数据。点间精度数据低于9.0%,相当于使用移液管手动点样体积。在26%至62%的Hct水平获得的定量结果中未观察到Hct效应。这些数据表明,我们基于微流控的采样程序是准确和精确的,并且Mavoglurant的分析不受Hct值的影响。这为使用固定体积的毛细血管血液进行 DBS 采样提供了一个简单的程序,可以消除与 DBS 样本分析相关的复发性 Hct 问题。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号