首页> 外文期刊>International Journal of Applied Engineering Research >Experimental Study of Pressure Drop and Heat Transfer Coefficients in a Packed Bed Column with Glass Beads
【24h】

Experimental Study of Pressure Drop and Heat Transfer Coefficients in a Packed Bed Column with Glass Beads

机译:玻璃珠填充床塔内压降和传热系数的实验研究

获取原文
获取原文并翻译 | 示例
       

摘要

Experimental investigation of convective heat transfer and pressure drop of a vertical upcoming liquid flow onto glass beads packed bed is undertaken. Two sizes of glass beads with 6.0 and 14.56mm diameter is considered for conducting experiments at two flow rates and different inlet water temperatures. The steady state temperature distributation along the bed is measured with data logger with 0.1 resolution of p-type thermocouples. The pressure drop, friction factor, local Nusselt number and steady state heat transfer coefficients are calculated. This work is systemically completed on the parametric studies on heat transfer and pressure drop. The heat transfer rate increases by 2.6% (ε = 0.49) and 4.5% ε = 0.387) when compared to bare tube (ε = 1.0). However, the relevant of experimental results are compared with available correlations in literature.
机译:对流传热和垂直即将到来的液体流向玻璃珠填充床的压降进行了实验研究。在两种流速和不同进水温度下进行实验时,考虑使用直径为6.0和14.56mm的两种尺寸的玻璃珠。使用数据分辨率为0.1的p型热电偶的数据记录仪测量沿床的稳态温度分布。计算压降,摩擦系数,局部努塞尔数和稳态传热系数。这项工作在传热和压降的参数研究上系统地完成了。与裸管(ε= 1.0)相比,传热率提高了2.6%(ε= 0.49)和4.5%ε= 0.387)。但是,将实验结果的相关性与文献中可用的相关性进行了比较。