The aim of this review was to evaluate whether CBCT is reliable for the detection of root fractures in teeth without root fillings, and whether the voxel size has an impact on diagnostic accuracy. The studies published in PubMed, Web of Science, ScienceDirect, Cochrane Library, Embase, Scopus, CNKI and Wanfang up to May 2014 were the data source. Studies on nonroot filled teeth with the i-CAT (n=8) and 3D Accuitomo CBCT (n=5) units were eventually selected. In the studies on i-CAT, the pooled sensitivity was 0.83 and the pooled specificity was 0.91; in the 3D Accuitomo studies, the pooled sensitivity was 0.95 and pooled specificity was 0.96. The i-CAT group comprised 5 voxel size subgroups and the 3D Accuitomo group contained 2 subgroups. For the i-CAT group, there was a significant difference amongst the five subgroups (0.125, 0.2, 0.25, 0.3 and 0.4mm; P=0.000). Pairwise comparison revealed that 0.125mm voxel subgroup was significantly different from those of 0.2, 0.25 and 0.3mm voxel subgroups, but not from the 0.4mm voxel subgroup. There were no significant differences amongst any other two subgroups (by =0.005). No significant difference was found between 0.08mm and 0.125mm voxel subgroups (P=0.320) for the 3D Accuitomo group. The present review confirms the detection accuracy of root fractures in CBCT images, but does not support the concept that voxel size may play a role in improving the detection accuracy of root fractures in nonroot filled teeth.
机译:这篇综述的目的是评估CBCT是否可用于检测没有牙根充填的牙齿中的牙根骨折,以及体素大小是否对诊断准确性有影响。数据来源截至PubMed,Web of Science,ScienceDirect,Cochrane图书馆,Embase,Scopus,CNKI和Wanfang截至2014年5月。最终选择了使用i-CAT(n = 8)和3D Accuitomo CBCT(n = 5)单元的非根充牙的研究。在i-CAT的研究中,合并敏感性为0.83,特异性为0.91。在3D Accuitomo研究中,合并敏感性为0.95,合并特异性为0.96。 i-CAT组包含5个体素大小的子组,而3D Accuitomo组包含2个子组。对于i-CAT组,五个亚组之间存在显着差异(0.125、0.2、0.25、0.3和0.4mm; P = 0.000)。配对比较显示,0.125mm体素亚组与0.2、0.25和0.3mm体素亚组有显着差异,但与0.4mm体素亚组无显着差异。其他两个亚组之间无显着差异(= 0.005)。对于3D Accuitomo组,在0.08mm和0.125mm体素子组之间(P = 0.320)没有发现显着差异。本综述证实了CBCT图像中牙根骨折的检测准确性,但不支持体素大小可能在提高非根充牙的牙根骨折检测准确性中发挥作用的概念。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号