Ex vivo evaluation of artifacts mimicking fracture lines on cone-beam computed tomography produced by different root canal sealers

机译:在不同根管封闭剂产生的锥形束计算机断层扫描上模拟骨折线的假体的离体评估

获取原文
获取原文并翻译 | 示例
           

摘要

Aim: To evaluate streaking artifacts produced by several root canal sealers on CBCT images with variations in voxel resolution. Methodology: Single-rooted premolars were selected and root filled using gutta-percha cones and one of the following sealers: Endofill, Sealer 26, Fillapex or AH Plus. Root canals filled only with gutta-percha were used as control. Scans of teeth using a small-volume CBCT were performed, and the images acquired were evaluated by two calibrated observers (k > 0.75). Artifacts were identified as streaks and dark bands on root dentine in axial slices with 2 voxel sizes (0.076 and 0.2 mm). Fisher's exact test (P < 0.05) was used to compare the presence/absence ratio of artifacts considering the factors 'sealer' and 'voxel size'. Results: For the 0.20 mm voxel size, Sealer 26 had significantly more artifacts than Fillapex (P = 0.006) or AH Plus (P = 0.017). No differences existed between the sealers when the 0.07 mm voxel size was used. Sealer 26 (P = 0.042) and Endofill (P = 0.035) had significantly more artifacts in the 0.20 mm voxel size than with the 0.076 mm voxel size, whilst no difference was noted for other filling conditions. Conclusions: The material used for root filling and the voxel resolution can influence the presence of streaking artifacts observed in CBCT images.
机译:目的:评估在体素分辨率变化的CBCT图像上由几个根管封闭器产生的裸露伪影。方法:选择单牙根前磨牙,并使用牙胶-牙锥和以下密封剂之一填充牙根:Endofill,Sealer 26,Fillapex或AH Plus。仅用牙胶填充的根管用作对照。使用小体积CBCT进行牙齿扫描,并由两名校准的观察者评估所采集的图像(k> 0.75)。在2个体素大小(0.076和0.2 mm)的轴向切片中,伪影被识别为根部牙质上的条纹和暗带。考虑因素“密封件”和“体素大小”,使用Fisher精确检验(P <0.05)比较伪影的存在/不存在比率。结果:对于0.20毫米体素尺寸,Sealer 26的假像明显多于Fillapex(P = 0.006)或AH Plus(P = 0.017)。当使用0.07 mm体素尺寸时,封口器之间没有差异。封口机26(P = 0.042)和Endofill(P = 0.035)在0.20 mm体素尺寸上比在0.076 mm体素尺寸上有更多的假象,而在其他填充条件下没有差异。结论:用于根填充的材料和体素分辨率可能会影响在CBCT图像中观察到的条纹痕迹的存在。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号