...
首页> 外文期刊>International endodontic journal >Degree of conversion of dual-cured resin cement light-cured through three fibre posts within human root canals: an ex vivo study.
【24h】

Degree of conversion of dual-cured resin cement light-cured through three fibre posts within human root canals: an ex vivo study.

机译:通过人的根管内的三个纤维柱光固化的双固化树脂水泥的转化度:一项离体研究。

获取原文
获取原文并翻译 | 示例

摘要

AIM: To evaluate the degree of conversion of one dual-cured resin cement light-cured through three fibre posts within extracted human teeth. METHODOLOGY: Fifteen mandibular premolars were root filled and then divided into three groups. Variolink II was light-cured through the posts (LP, D.T. Light-Post; PP, FRC Postec Plus; SP, Snowpost) within the root canal. The degree of conversion was obtained at 1 mm intervals in 9 mm-deep longitudinally sectioned root canals using an optical microscope connected to an FTIR spectrophotometer (n = 10). The light transmission of each post tested was also examined using UV-Vis spectroscopy. Data were analysed using ANOVA and Tukey's test (alpha = 0.05). RESULTS: The LP and PP posts revealed a light transmission of 10.2% and 7.7%, respectively, whereas the SP post exhibited a significantly lower value of 0.5%. The degree of conversion mean value ranged from 32.78% to 69.73% depending on the depth and type of post. For all the groups, there were significant decreases in the degree of conversion values for the middle region when compared with those for the cervical region (P < 0.05). Except at a depth of 1 mm, the SP group consistently exhibited significantly lower degree of conversion values than the other groups (P < 0.05). The linear regression analysis revealed a strong correlation between the light transmission of the posts and the overall degree of conversion value for each group (R(2) = 0.9888). CONCLUSIONS: The decrease in the degree of conversion for Variolink II relative to the depth was dependent on the light transmission capacity of the posts tested.
机译:目的:评估通过提取的人牙内的三个纤维柱轻固化的一种双固化树脂水泥的转化程度。方法:将15个下颌前磨牙进行根充,然后分为三组。 Variolink II通过根管内的柱子(LP,D.T。Light-Post; PP,FRC Postec Plus; SP,Snowpost)进行光固化。使用连接到FTIR分光光度计(n = 10)的光学显微镜,在9毫米深的纵切的根管中以1毫米的间隔获得转化度。还使用UV-Vis光谱法检查了每个测试后的光透射率。使用方差分析和Tukey检验分析数据(alpha = 0.05)。结果:LP柱和PP柱的透光率分别为10.2%和7.7%,而SP柱的透光率则低得多,为0.5%。转换程度平均值的范围从32.78%到69.73%,具体取决于帖子的深度和类型。与宫颈区域相比,所有组中部区域的转化率值均显着降低(P <0.05)。除1 mm的深度外,SP组始终显示出比其他组低得多的转化率值(P <0.05)。线性回归分析显示,每组的透光率与总转化度值之间具有很强的相关性(R(2)= 0.9888)。结论:Variolink II相对于深度的转换程度降低取决于被测柱的透光能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号