Aim: To measure differences between single (STI) and multiple teeth isolation (MTI), pulpal blood flow (PBF) was assessed using laser Doppler flowmetry (LDF). Methodology: Pulpal blood flow of twenty maxillary incisors with no restorations or abnormal responses to sensitivity tests in healthy patients between 24 and 42 years of age was measured in perfusion units (PU). STI (isolation of only the tooth undergoing blood flow assessment) and MTI (isolation including the maxillary right to the maxillary left canine) recordings were taken with regular blood flow (RBF) and with local infiltration (LI) with vasoconstrictor. anova and Tukey HSD tests were used for statistical analysis. Results: The mean PBF with regular blood flow conditions was significantly different between single tooth isolation [5.53 PU (SD ± 2.98)] and multiple tooth isolation [2.85 PU (SD ± 2.13)] (P < 0.01). When local anaesthesia was administered (LI), the PBF was significantly different between single tooth isolation [2.95 PU (SD ± 2.48)] and multiple tooth isolation [1.32 PU (SD ± 0.70)] (P < 0.05). Significant differences in PBF also existed between single tooth isolation under regular blood flow conditions and with local anaesthesia (P < 0.01), between single tooth isolation under regular blood flow conditions and multiple tooth isolation with local anaesthesia (P < 0.01), and between multiple tooth isolation under regular blood flow conditions and with local anaesthesia (P < 0.05). Conclusions: Pulpal blood flow measurements could be obtained with multiple teeth isolation and single tooth isolation. Multiple teeth isolation blocked signal contamination better. Single tooth isolation provided significantly different readings for regular blood flow and LI conditions and may therefore provide an option for pulpal blood flow assessment with LDF.
机译:目的:为了测量单齿(STI)和多齿分离(MTI)之间的差异,使用激光多普勒血流仪(LDF)评估了牙髓血流量(PBF)。方法:在24至42岁的健康患者中,以灌注单位(PU)测量了20颗上颌切牙的牙髓血流量,这些牙没有恢复或对敏感性测试没有异常反应。 STI(仅对接受血流评估的牙齿进行隔离)和MTI(包括上颌右犬至上颌左犬的隔离)记录均采用常规血流(RBF)和血管收缩剂进行局部浸润(LI)。使用方差分析和Tukey HSD测试进行统计分析。结果:单齿隔离度[5.53 PU(SD±2.98)]和多齿隔离度[2.85 PU(SD±2.13)]之间,正常血流条件下的平均PBF显着不同(P <0.01)。当进行局部麻醉(LI)时,单牙隔离[2.95 PU(SD±2.48)]和多牙隔离[1.32 PU(SD±0.70)]之间的PBF显着不同(P <0.05)。在常规血流条件下单牙隔离和局部麻醉下(P <0.01),常规血流条件下单牙隔离和局部麻醉下多齿隔离(P <0.01)以及在多次麻醉下多牙隔离之间的PBF也存在显着差异。在常规血流条件下并局部麻醉下进行牙齿隔离(P <0.05)。结论:多牙隔离和单牙隔离可以测量牙髓的血流量。多齿隔离可以更好地阻止信号污染。单颗牙齿的隔离对于正常的血流和LI条件提供了明显不同的读数,因此可以为使用LDF进行牙髓血流评估提供选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号