Aim To investigate the ability of swept-source optical coherence tomography (SS-OCT) to detect incomplete crown fractures (cracks) in extracted teeth. Methodology Cracks were created by subjecting 30 porcine premolars to impaction by a steel rod plunging from the occlusal tip. SS-OCT images and stereomicroscopic photographs of the surface were acquired for each specimen before and after impaction. For evaluation, the focused light beam of SS-OCT was projected from three directions on the same plane: buccal or lingual, 45° to the mesial, and 45° to the distal. Histological sections were prepared after impaction, and length and width of cracks and lamellae were evaluated using the corresponding SS-OCT image. The values were analysed using Pearson's correlation coefficient. Results Through SS-OCT, cracks and lamellae were clearly detected as intensified scattering signals at the same position on the corresponding microphotographs and histological sections. Amongst the three scanning angles, the greatest lengths and widths were considered the corresponding values of SS-OCT and were used for analysis. Significant correlations regarding line length and width were observed between SS-OCT and histological sections (length: r=0.65, P<0.001; width: r=0.60, P<0.001). Conclusions SS-OCT can clearly discriminate cracks, which appear as highlighted lines due to the scattering of light. The results obtained from the three scanning directions were correlated well with those of the histological sections.
机译:目的探讨扫频光学相干断层扫描(SS-OCT)检测拔出牙齿中不完全的冠状骨折(裂纹)的能力。方法学裂纹是通过使30头猪前磨牙受从咬合尖端插入的钢棒撞击而产生的。在撞击之前和之后,为每个样本获取表面的SS-OCT图像和立体显微镜照片。为了进行评估,SS-OCT的聚焦光束从同一平面上的三个方向投射:颊侧或舌侧,与内侧成45°,与远端成45°。撞击后准备组织切片,并使用相应的SS-OCT图像评估裂缝和薄片的长度和宽度。使用皮尔森相关系数分析这些值。结果通过SS-OCT,在相应的显微照片和组织切片上,在相同位置清楚地检测到裂纹和薄片为增强的散射信号。在这三个扫描角中,最大的长度和宽度被认为是SS-OCT的对应值,并用于分析。在SS-OCT与组织切片之间观察到关于线长和线宽的显着相关性(长度:r = 0.65,P <0.001;宽度:r = 0.60,P <0.001)。结论SS-OCT可以清楚地区分裂纹,由于光的散射,裂纹显示为高亮线。从三个扫描方向获得的结果与组织切片的相关性很好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号