首页> 外文期刊>Journal of Structural Engineering >Cover-Plate and Flange-Plate Steel Moment-Resisting Connections
【24h】

Cover-Plate and Flange-Plate Steel Moment-Resisting Connections

机译:盖板和法兰板钢制抗力矩连接

获取原文
获取原文并翻译 | 示例

摘要

Nonlinear finite-element modeling of steel moment-resisting connections reinforced with steel plates was undertaken as part of the second phase of the SAC project. Five cover-plate and five flange-plate connections of W143176 columns to W30399 beams were studied. Connections reinforced with cover plates or flange plates will perform substantially better than unreinforced connections. Flange-plate connections are likely superior to cover-plate connections. Rectangular reinforcing plates are superior to trapezoidal shaped plates. Three-sided fillet welds should be used to join reinforcing plates to beam flanges. Bracing the beam flanges outside the plastic hinge remote from the column face to delay lateral-torsional buckling is not necessary. Beam web reinforcement at the column face does not affect the transfer of shear force from the reinforced beam to the column. Beam theory should not be used to estimate stresses in reinforced connections.
机译:作为SAC项目第二阶段的一部分,对钢板加固的钢制抗弯连接进行了非线性有限元建模。研究了W143176柱与W30399梁的5个盖板和5个法兰板连接。用盖板或法兰板加固的连接将比未加固的连接性能好得多。法兰板连接可能优于盖板连接。矩形增强板优于梯形板。应使用三面角焊缝将增强板连接到梁法兰上。无需在远离柱面的塑料铰链外支撑梁法兰以延迟横向扭转屈曲。柱面的梁腹板加固不影响从加固梁到柱的剪切力传递。梁理论不应用于估计加固连接中的应力。