Aim: To evaluate the effect of an apical negative pressure system, a passive ultrasonic irrigation system and a combination of both apical negative pressure and passive ultrasonic irrigation on the penetration of the irrigating contrast solution (ICS) up to working length and into simulated lateral canals. Methodology: The root canals of 64 single-rooted teeth were instrumented using the ProTaper rotary system. In each sample, three simulated lateral canals were created at 2, 4 and 6 mm levels from the root apex using a 06-size C+ file (Dentsply Maillefer, Ballaigues, Switzerland). Samples were randomly assigned into 4 experimental groups (n = 16): group I - conventional needle irrigation, group II - passive ultrasonic irrigation, group III - apical negative irrigation system and group IV - combination of passive ultrasonic irrigation and apical negative pressure irrigation system. To examine irrigating solution penetration, Indian ink was mixed with 5.25% NaOCl and delivered into the root canals. Samples were then assessed by direct observation of the images taken using Canon EOS rebel T3. The depth of penetration of ICS up to the working length and into the simulated lateral canals was analysed using chi-squared tests. Results: The combination (ANP and PUI) and ANP group had significantly deeper ICS penetration up to the working length (P < 0.001). The combination (ANP and PUI) and the PUI group exhibited significantly greater ICS penetration into lateral canals at the 6 mm level (P < 0.001). At the 4 and 2 mm levels, the combination of ANP and PUI had significantly greater ICS penetration into the lateral canals than the other groups (P < 0.001). Conclusions: The combination of ANP and PUI was the only group able to achieve irrigating contrast solution penetration both up to the working length and into lateral canals.
机译:目的:为了评估根尖负压系统,无源超声冲洗系统以及根尖负压和无源超声冲洗的组合对冲洗造影剂(ICS)直至工作长度和模拟侧管的渗透的影响。方法:使用ProTaper旋转系统对64根单根牙齿的根管进行测量。在每个样品中,使用06尺寸的C +锉刀(Dentsply Maillefer,Ballaigues,瑞士)在距根尖2、4和6毫米处创建三个模拟的侧管。将样品随机分为4个实验组(n = 16):第一组-常规针刺冲洗,第二组-被动超声冲洗,第三组-顶负冲洗系统和第四组-被动超声冲洗和顶负压冲洗系统的组合。为了检查灌溉溶液的渗透性,将印度墨水与5.25%NaOCl混合,然后输送到牙根管中。然后通过直接观察使用佳能EOS rebel T3拍摄的图像来评估样品。使用卡方检验分析了ICS直至工作长度并进入模拟侧管的深度。结果:ANP和PUI的组合与ANP组相比,在达到工作长度时,ICS的穿透力更深(P <0.001)。组合(ANP和PUI)和PUI组在6 mm的水平上表现出更大的ICS渗透入侧管的能力(P <0.001)。在4mm和2mm的水平上,ANP和PUI的组合比其他组具有更大的ICS渗透入侧管(P <0.001)。结论:ANP和PUI的组合是唯一能够在整个工作长度和侧管内实现冲洗液穿透力的组。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号