Reproducibility of Human Kidney Perfusion and Volume Determinations with Electron Beam Computed Tomography

机译:使用电子束计算机断层扫描进行人肾灌注和体积测定的可重复性

获取原文
获取外文期刊封面目录资料

摘要

RATIONALE AND OBJECTIVESAlterations in whole kidney, cortical, and medullary perfusion and volume play a pivotal role in various physiologic and pathophysiologic processes. Electron-beam computed tomography (EBCT) provides accurate measurements of these traits in animals, but their reproducibility in humans has not been established.METHODSPerfusion, volume, and flow measurements were obtained by EBCT in eight healthy human volunteers under controlled conditions on two consecutive days.RESULTSMean values for whole kidney, cortical, and medullary perfusion and volume obtained with EBCT were similar in scan 1 and scan 2 (P> 0.1), and correlated highly. Coefficients of variation for the repeated measurements usually were less than 10. Values obtained for renal regional perfusion and volume agreed with previously reported values.CONCLUSIONSElectron-beam computed tomography estimates of single whole kidney, cortical, and medullary perfusions and volumes are highly reproducible in normal humans, and may be useful to advance understanding of renal involvement in human disease.
机译:基本原理和目标全肾、皮质和髓质灌注和体积在各种生理和病理生理过程中起着关键作用。电子束计算机断层扫描 (EBCT) 可在动物身上准确测量这些性状,但尚未确定它们在人类中的可重复性。方法在对照条件下连续2天对8名健康人类志愿者进行EBCT测定输液、体积和流量。结果EBCT全肾、皮质、髓质灌注和体积在扫描1和扫描2中相似(P> 0.1),且高度相关。重复测量的变异系数通常小于10%。获得的肾脏区域灌注值和体积与先前报告的值一致。结论单个全肾、皮质和髓质灌注和体积的电子束计算机断层扫描估计在正常人中具有高度可重复性,可能有助于增进对肾脏参与人类疾病的理解。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号