Using multiple probes at the maximum points of radiation helps achieve 200 V/m within the test boundaries.A CHIEVING THE MIL-STD-461E MAN-dated 200 volts/meter within the 30-MHz to 200-MHz frequency spectrum in the presence of a ground plane can be quite difficult. A biconical antenna is generally used in this frequency spectrum, as shown in Figure 1. The maximum input power to this antenna is typically 2000 watts continuous. Achieving a 200-volt/meter test level would require the use of a 2000-watt amplifier in this frequency band when configured at 1 meter or less in front of the unit-under-test (UUT). Effective monitoring of the voltage from the transmit antenna would require the use of a broadband sensor with monitor such as the Amplifier Research FM 5004 Field Monitor, along with AR's FP 5000 Field Probe.
机译:在辐射的最大点使用多个探头有助于在测试范围内达到200 V / m。在存在以下情况的情况下,在30 MHz至200 MHz频谱内达到MIL-STD-461E MAN规定的200 V /米接地平面可能非常困难。如图1所示,通常在该频谱中使用双锥形天线。该天线的最大输入功率通常为2000瓦连续。要达到200伏/米的测试水平,在被测单元(UUT)前面配置为1米或以下时,需要在该频带中使用2000瓦的放大器。要有效监控发射天线的电压,将需要使用带有传感器的宽带传感器,例如Amplifier Research FM 5004现场监测器以及AR的FP 5000现场探头。