首页> 外文期刊>Intensive care medicine >Dynamic elastic pressure-volume loops in healthy pigs recorded with inspiratory and expiratory sinusoidal flow modulationRelationship to static pressure-volume loops.
【24h】

Dynamic elastic pressure-volume loops in healthy pigs recorded with inspiratory and expiratory sinusoidal flow modulationRelationship to static pressure-volume loops.

机译:记录有吸气和呼气正弦流量调制的健康猪中的动态弹性压力-体积环与静态压力-体积环的关系。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE. The objective was to analyse relationships between inspiratory and expiratory static and dynamic elastic pressure-volume (P(el)/V) curves in healthy pigs. DESIGN. The modulated low flow method was developed to allow studies also of the expiratory P(el)/V curves. Static P(el)/V (P(el,st)/V) and dynamic P(el)/V (P(el,dyn)/V) loops were studied in healthy pigs. SETTING. Animal research laboratory in a university hospital. MATERIAL. Ten healthy anaesthetised and paralysed pigs. INTERVENTIONS AND MEASUREMENTS. A computer controlled a Servo Ventilator 900C with respect to respiratory rate, inspiratory flow and expiratory pressure to achieve a sinusoidal modulation of inspiration and expiration for determination of P(el,dyn)/V loops from zero end-expiratory pressure (ZEEP) and from a positive end-expiratory pressure (PEEP) of 6 cmH(2)O to 20, 35 and 50 cmH(2)O. The same system was used for studies of P(el,st)/V loops with the flow-interruption method from ZEEP and PEEP to 35 cmH(2)O. Recordings were analysed with an iterative technique. RESULTS. The feasibility of automated determination of P(el,dyn)/V loops was demonstrated. Differences between P(el,dyn)/V and P(el,st)/V loops were explained by viscoelastic behaviour. P(el,st)/V loops recorded from PEEP to 35 cmH(2)O showed no significant hysteresis, indicating a non-significant surface tension hysteresis. P(el,dyn)/V loops from PEEP and both P(el,st)/V and P(el,dyn)/V loops from ZEEP to 35 cmH(2)O showed hysteresis. This indicates that lung collapse/re-expansion caused P(el)/V loop hysteresis which, in P(el,dyn)/V loops, was augmented by viscoelastic behaviour. CONCLUSIONS. Viscoelasticity influences P(el,dyn)/V curves. Hysteresis caused by surface tension merits re-evaluation. Lung collapse and re-expansion may be indicated by hysteresis of P(el)/V loops.
机译:目的。目的是分析健康猪的吸气和呼气静态和动态弹性压力-体积(P(el)/ V)曲线之间的关系。设计。开发了调制低流量方法以允许研究呼气P(el)/ V曲线。在健康猪中研究了静态P(el)/ V(P(el,st)/ V)和动态P(el)/ V(P(el,dyn)/ V)回路。设置。大学医院的动物研究实验室。材料。十只健康的麻醉和瘫痪猪。干预和测量。计算机控制伺服呼吸机900C的呼吸频率,吸气流量和呼气压力,以实现吸气和呼气的正弦调制,从而从零呼气末压力(ZEEP)和吸气末期确定P(el,dyn)/ V回路。 6 cmH(2)O至20、35和50 cmH(2)O的呼气末正压(PEEP)。使用相同的系统通过ZEEP和PEEP至35 cmH(2)O的流动中断方法研究P(el,st)/ V回路。使用迭代技术分析记录。结果。证明了自动确定P(el,dyn)/ V回路的可行性。 P(el,dyn)/ V和P(el,st)/ V回路之间的差异由粘弹性行为解释。从PEEP记录到35 cmH(2)O的P(el,st)/ V回路无明显滞后现象,表明表面张力无明显滞后现象。 PEEP的P(el,dyn)/ V回路以及ZEEP至35 cmH(2)O的P(el,st)/ V和P(el,dyn)/ V回路均显示出滞后现象。这表明肺塌陷/再扩张引起的P(el)/ V回路滞后,在P(el,dyn)/ V回路中,粘弹性增加了。结论。粘弹性影响P(el,dyn)/ V曲线。由表面张力引起的磁滞值得重新评估。 P(el)/ V回路的滞后可能表明肺部塌陷和再次扩张。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号