首页> 外文期刊>Intensive and critical care nursing >Reliability and validity assessment of the Japanese version of the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU)
【24h】

Reliability and validity assessment of the Japanese version of the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU)

机译:日文版《重症监护病房(CAM-ICU)混乱评估方法》的信度和效度评估

获取原文
获取原文并翻译 | 示例
           

摘要

Objective: Delirium may lead to adverse outcomes in patients with serious conditions, but is often under-diagnosed due to inadequate screening. The Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) is an established method for assessing delirium in the ICU. The validity and reliability of the Japanese version of the CAM-ICU has not, however, been verified, and we undertook this study to verify these parameters. Research methodology: CAM-ICU validity and reliability were assessed in two Japanese ICUs. Using the evaluation of the DMS-IV-TR in the psychiatrists group as the standard criteria for delirium diagnosis, we compared the evaluation of the Japanese version of the CAM-ICU between the research nurses group and the staff nurses group. Results: According to DSM-IV-TR criteria, the prevalence of delirium was 22.0%, and according to CAM-ICU delirium was found in 22.0% with Research Nurses and 19.5% with Staff Nurses. CAM-ICU sensitivity ratings were 83% and 78%, while their specificity ratings were 95% and 97%, respectively. The Kappa inter-rater reliability was good (. κ=. 0.85), and Cronbach's alpha coefficient was 0.69 (95% CI: 0.57-0.79). Mean rating time for the CAM-ICU was 2.5-2.8. minutes for Research Nurses and Staff Nurses, respectively. Conclusion: The Japanese version of the CAM-ICU has comparable validity and reliability as a delirium assessment tool in surgical patients in two Japanese ICUs. With training, CAM-ICU can be incorporated into daily clinical practice.
机译:目的:Deli妄可能导致重症患者出现不良后果,但由于筛查不充分,常常被误诊。重症监护病房(CAM-ICU)的混乱评估方法是一种评估ICU中del妄的既定方法。但是,尚未验证日文版CAM-ICU的有效性和可靠性,因此我们进行了这项研究以验证这些参数。研究方法:在两个日本ICU中评估了CAM-ICU的有效性和可靠性。使用精神科医生组中DMS-IV-TR的评估作为del妄诊断的标准,我们比较了研究护士组和职员护士组对日文版CAM-ICU的评估。结果:根据DSM-IV-TR标准,of妄的患病率为22.0%,根据CAM-ICU,研究护士中Staff妄的发生率为22.0%,职员护士中19.妄的发生率为19.5%。 CAM-ICU灵敏度等级分别为83%和78%,而特异性等级分别为95%和97%。 Kappa评分者之间的信度良好(。κ= 0.85),Cronbach的alpha系数为0.69(95%CI:0.57-0.79)。 CAM-ICU的平均评级时间为2.5-2.8。分钟分别是研究护士和参谋护士的时间。结论:日文版CAM-ICU作为as妄评估工具在两个日本ICU中的手术患者中具有相当的有效性和可靠性。通过培训,可以将CAM-ICU纳入日常临床实践。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号