The operation of conductors and contact connections in electric circuits transmitting megaampere-current pulses with durations of tens of microseconds is considered. The permissible conductor-current density is determined from the condition of thermal stability of the high-voltage polymeric insulation. Operating conditions of demountable contact connections for megaampere pulse currents are described, and design examples of such connections operating at a linear current density as high as 80 kA/cm are given. Methods for providing mechanical stability against the action of electrodynamic forces that occur during the passage of megaampere-current pulses are considered.
机译:考虑了持续数十微秒的传输兆安电流脉冲的电路中导体和触点连接的操作。允许的导体电流密度由高压聚合物绝缘的热稳定性条件确定。描述了用于兆安培脉冲电流的可拆卸触点连接的工作条件,并给出了在高达80 kA / cm的线性电流密度下工作的此类连接的设计示例。考虑了提供机械稳定性以抵抗兆安培电流脉冲通过期间发生的电动势作用的方法。