The LIU-2 induction accelerator is described. It is used as an injector for the developed large linear induction accelerator with a maximum electron beam energy of 20 MeV, which is intended for small-angle pulse X-ray tomography. Owing to the good quality and high current of the electron beam (2 kA), the injector is capable of operating as an independent X-ray source with an electron energy of 2 MeV, the beam diameter at the target of <2 mm, and a pulse duration of 200 ns. The total yield of the bremsstrahlung energy is 52.4 J and the fraction of quanta with energies of >1 MeV is ~20% of the total energy yield. The spread of the radiation intensity in the solid angle of 10° is ±5%, and the absorbed dose at a distance of 1 m from the target is 32 × 10~(-3) Gy, which allows this source to be used with attenuation of 10~3-10~4 for exposure of available X-ray films. This type of system is characterized by a high transmission capability with a 0.5-mm maximum spatial resolution of X-ray images and can be used in the X-ray imaging technique when carrying out gas-dynamic testing of products with an optical thickness as great as 90 mm of lead equivalent.