首页> 外文期刊>Instruments and Experimental Techniques >Multichannel Wire Gas Electron Multipliers with 1- and 3-mm Gaps
【24h】

Multichannel Wire Gas Electron Multipliers with 1- and 3-mm Gaps

机译:具有1毫米和3毫米间隙的多通道气体电子倍增器

获取原文
获取原文并翻译 | 示例

摘要

The operation of multichannel wire gas electron multipliers (MWGEMs) with gaps between electrodes δ = 1 and 3 mm, when the chamber is filled with commercial neon under a 0.4- and 1.0-atm (abs.) pressure and irradiated with α and β particles, is studied. The following maximal proportional electron multiplication coefficients are obtained: 6 × 10~3 (α, irradiation, δ = 3 mm, 1 atm, and 20% streamers), 1.2 × 10~4 (β~-, 3 mm, 1 atm, and 50% streamers), 6 × 10~3 (α, 3 mm, 0.4 atm, and 20% streamers), and 10~5 ((β~-, 3 mm, 0.4 atm, and 50% streamers). The maximal proportional electron multiplication coefficients are obtained in the MWGEM and its anode (induction) gap in the sequential electron multiplication mode: 1.08 × 10~5 (β~-, 1 mm, 0.4 atm, 50% streamers), 2 × 10~6 (β~-, 3 mm, 0.4 atm, 20% streamers), and 1.12 × 10~3 (α, 3 mm, 0.4 atm, 50% streamers).
机译:当在0.4和1.0 atm(绝对)的压力下用商业氖气填充腔室并用α和β粒子辐照时,在电极δ= 1和3 mm之间具有间隙的多通道线型气体电子倍增器(MWGEM)的操作,正在研究中。获得以下最大比例电子倍增系数:6×10〜3(α,辐射,δ= 3 mm,1 atm,和20%的色带),1.2×10〜4(β〜-,3 mm,1 atm,和50%的拖缆),6×10〜3(α,3 mm,0.4 atm和20%的拖缆)和10〜5((β〜-,3 mm,0.4 atm和50%的拖缆)。在MWGEM及其阳极(感应)间隙中以顺序电子倍增模式获得比例电子倍增系数:1.08×10〜5(β〜-,1 mm,0.4 atm,50%流光),2×10〜6( β〜-,3 mm,0.4 atm,20%彩带)和1.12×10〜3(α,3 mm,0.4 atm,50%彩带)。