...
首页> 外文期刊>Instrumentation science & technology: Designs and applications for chemistry, biotechnology, and environmental science >Simultaneous Determination of Six Trace Elements in Plant Medicines by Derivative Adsorption Waves in Conjunction with a Microwave Technique
【24h】

Simultaneous Determination of Six Trace Elements in Plant Medicines by Derivative Adsorption Waves in Conjunction with a Microwave Technique

机译:微波导数吸收波同时测定植物药材中的六种微量元素

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Complex adsorption waves of Cu(II), Pb(II), Cd(II), Ni(II), Co(II), and Zn(II) in substrate solution (pH=9.26) of diacetyldioxime-ammonia-ammonium chloridesodium citrate-gelatin-sodium sulfite were studied and a new method for determination of the six trace elements in aqueous solutions was developed. The results show that there are sensitive adsorption waves of Cu(II), Pb(II), Cd(II), Ni(II), Co(II), and Zn(II) complexes at about -0.45, -0.61,-0.78, -1.07, -1.23, and -1.38 V, respectively. The method is easy to operate and is able to determine these trace elements in aqueous solutions rapidly and simultaneously. When the signal-to-noise ratio equals 3, the detection limits of copper, lead, cadmium, nickel, cobalt, and zinc are 3.2 × 10{sup}(-4), 4.8 × 10{sup}(-3), 1.9 × 10{sup}(-3), 1.7 × 10{sup}(-5), 2.1 × 10{sup}(-6), and 1.0 × 10{sup}(-3) mg/cm{sup}3. Good linear relationships exist between the concentrations and the current peaks when copper, lead, cadmium, nickel, cobalt, and zinc concentrations are within 6.5 × 10{sup}(-4) ~ 10{sup}0, 9.3 × 10{sup}(-3)~10, 4.1 × 10{sup}(-3)~10, 3.2 × 10{sup}(-5)~10{sup}(-1), 4.0 × 10{sup}(-6)~10{sup}(-2), and 2.1 × 10{sup}(-3)~10 μg/cm{sup}3, respectively. In conjunction with a microwave assimilation technique, the method has been used in the rapid and simultaneous determination of these trace elements in some plant medicines with satisfactory results.
机译:二乙酰基二肟-氨-氯化铵柠檬酸钠溶液(pH = 9.26)中的Cu(II),Pb(II),Cd(II),Ni(II),Co(II)和Zn(II)的复合吸附波-明胶-亚硫酸钠的研究,开发了一种测定水溶液中六种微量元素的新方法。结果表明,Cu(II),Pb(II),Cd(II),Ni(II),Co(II)和Zn(II)配合物存在敏感的吸附波,其吸附波长约为-0.45,-0.61,-分别为0.78,-1.07,-1.23和-1.38V。该方法易于操作,并且能够快速,同时测定水溶液中的这些微量元素。当信噪比等于3时,铜,铅,镉,镍,钴和锌的检出限为3.2×10 {sup}(-4),4.8×10 {sup}(-3), 1.9×10 {sup}(-3),1.7×10 {sup}(-5),2.1×10 {sup}(-6)和1.0×10 {sup}(-3)mg / cm {sup} 3。当铜,铅,镉,镍,钴和锌的浓度在6.5×10 {sup}(-4)〜10 {sup} 0、9.3×10 {sup}范围内时,浓度与电流峰值之间存在良好的线性关系。 (-3)〜10,4.1×10 {sup}(-3)〜10,3.2×10 {sup}(-5)〜10 {sup}(-1),4.0×10 {sup}(-6)分别约为〜10 {sup}(-2)和2.1×10 {sup}(-3)〜10μg/ cm {sup} 3。结合微波同化技术,该方法已用于快速,同时测定某些植物药物中的微量元素,结果令人满意。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号