首页> 外文期刊>Chemistry of Materials: A Publication of the American Chemistry Society >Main-chain chiral smectic polymers showing a large electroclinic effect in the SmA* phase
【24h】

Main-chain chiral smectic polymers showing a large electroclinic effect in the SmA* phase

机译:主链手性化妆品在SmA*相中显示出较大的电临床效应

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

The synthesis and characterization of a main-chain smectic liquid-crystalline polymer system designed for development into electromechanical actuators is described. The chemical structure is chosen to provide a large electroclinic effect in the SmA* phase, with large concomitant layer shrinkage (a rare combination). The polymers are prepared by acyclic diene metathesis polymerization (ADMET) of liquid-crystalline alpha,omega-dienes. Oligomers with a degree of polymerization of similar to 10-30 are obtained using Grubbs first-generation catalyst, while oligomers with a degree of polymerization of similar to 200 are obtained using Grubbs second-generation catalyst. All polymer samples show the following phase sequence: I - SmA* - SmC* Glass. X-ray analysis of polymer powder samples demonstrates the desired layer shrinkage at the SmA* - SmC* transition. The polymers form well-aligned fibers by pulling from the isotropic melt, and X-ray analysis of fibers in the SmA* phase shows that in the bulk of the fiber the layers are oriented perpendicular to the fiber axis, while at the surfaces there appears to be a thin sheath where the layers are parallel to the fiber/air interface. The desired layer shrinkage with tilt at the SmA* - SmC* transition in these fibers is seen as well, and in the SmC* phase the fibers exhibit an interesting conical chevron layer structure. Electro-optic investigation of aligned thin films of the polymer, prepared from quenched fiber glasses using a novel technique, exhibit a large electroclinic effect, with substantial degradation of alignment quality upon field-induced tilt. This degradation in alignment quality, coupled with the layer shrinkage at the SmA* - SmC* transition demonstrated by X-ray scattering, strongly suggests the desired layer shrinkage with electroclinic tilt is in fact occurring in the polymer films.
机译:描述了设计用于开发机电致动器的主链中型液晶聚合物系统的合成和表征。选择这种化学结构是为了在SmA*相中提供较大的电临床效应,并伴随较大的层收缩(罕见的组合)。采用液晶α,omega-二烯的无环二烯复分解聚合(ADMET)制备了聚合物。使用Grubbs第一代催化剂获得聚合度接近10-30的低聚物,而使用Grubbs第二代催化剂获得聚合度相似于200的低聚物。所有聚合物样品都显示出以下相序:I - SmA* - SmC* 玻璃。聚合物粉末样品的 X 射线分析表明,在 SmA* - SmC* 转变处具有所需的层收缩率。聚合物通过从各向同性熔体中拉出形成排列良好的纤维,对 SmA* 相中纤维的 X 射线分析表明,在大部分光纤中,层的方向垂直于纤维轴,而在表面上似乎有一个薄的护套,其中层平行于纤维/空气界面。在这些纤维中,还看到了在SmA*-SmC*跃迁处倾斜的所需层收缩,并且在SmC*相中,纤维表现出有趣的锥形人字形层结构。使用新技术从淬火纤维玻璃制备的聚合物取向薄膜的电光研究表现出很大的电诊所效应,在现场诱导倾斜时取向质量显着下降。这种取向质量的下降,加上 X 射线散射所证明的 SmA* - SmC* 转变处的层收缩,强烈表明在聚合物薄膜中实际上发生了电斜倾斜所需的层收缩。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号