A new rotating-disk sorptive extraction mode, with a copolymer of divinylbenzene and N-vinylpyrrolidone trapped in the cavity of the disk, used for determination of florfenicol residues in porcine plasma

机译:A new rotating-disk sorptive extraction mode, with a copolymer of divinylbenzene and N-vinylpyrrolidone trapped in the cavity of the disk, used for determination of florfenicol residues in porcine plasma

获取原文
获取原文并翻译 | 示例
           

摘要

A novel extraction approach was developed based on rotating-disk sorptive extraction (RDSE). In this approach the rotating-disk extraction device consists of a Teflon disk, with a cavity that is loaded with a commercial sorbent phase selected according to the polarity of the analyte. To avoid leakage of the sorbent, the cavity is covered with a fiberglass filter and sealed with a Teflon ring. The proposed novel analytical RDSE technique was used in this study to determine florfenicol levels in plasma as a model analyte, or sample system, to describe the pharmacokinetics of a veterinary formulation. The sorbent used for this application was the copolymer of divinylbenzene and N-vinylpyrrolidone (Oasis HLB), which was selected because the florfenicol molecule contains both hydrophilic and lipophilic moieties. After the extraction, final determination of the analyte was performed by HPLC-DAD. Calibration plots and other analytical features were obtained after 90 min of extraction. The calibration plot was linear over the interval 0.4-16 μg mL~(-1) (n=6), with R~2= 0.9999. Recovery and repeatability were determined using a blank plasma sample spiked with 4.8 μg mL~(-1) florfenicol. A recovery of 91.5 , with a relative standard deviation (RSD) of 8.8 , was obtained when the extraction was evaluated using six different rotating-disk devices. Precision was also assessed, using the same disk (containing the same sorbent phase) for eight aliquots of the same sample. The RSD under these conditions was 10.2 , clearly indicating that the sorptive phase could possibly be re-used. Accordingly, RDSE is a suitable sample preparation alternative to liquid-liquid extraction (LLE), solid-phase extraction (SPE), and stir-bar sorptive extraction (SBSE).

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号