...
首页> 外文期刊>Annals of clinical biochemistry. >Measurement of total homocysteine in plasma and blood spots using liquid chromatography-tandem mass spectrometry: comparison with the plasma Abbott IMx method.
【24h】

Measurement of total homocysteine in plasma and blood spots using liquid chromatography-tandem mass spectrometry: comparison with the plasma Abbott IMx method.

机译:使用液相色谱-串联质谱法测定血浆和血斑中的总同型半胱氨酸:与血浆Abbott IMx方法进行比较。

获取原文
获取原文并翻译 | 示例

摘要

BACKGROUND: Current sampling for total homocysteine (tHcy) is problematic, requiring plasma separation within 15 min. The aim of this study was to develop a liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method for the measurement of tHcy in plasma and dried blood spots and to determine whether the dried blood spot concentration could be used to predict plasma concentrations of tHcy. METHODS: LC-MS/MS methodology was optimized to measure tHcy in plasma and dried blood spots. Fifty blood samples collected from heart transplant patients were used to form dried blood spots and for plasma analysis. Plasma tHcy was also measured using the Abbott IMx(1) method and values were compared to the tHcy concentrations determined in plasma and dried blood spots using LC-MS/MS methodology. RESULTS: The plasma tHcy LC-MS/MS results compared well with the IMx values: LC-MS/MS=1.18(IMx)-0.44 (r(2)=0.915). The within-batch precision (n =10) of the plasma LC-MS/MS method was < 2.0% at 14.6 and 37.7 micro mol/L, respectively; the between-batch precision (n=10) was 5.0 and 8.0%, respectively, at these concentrations. The method was found to be sensitive down to 1 micro mol/L and linear up to at least 100 micro mol/L. Dried blood spot LC-MS/MS results were considerably lower than the plasma IMx values (P < 0.0001): dried blood spot LC-MS/MS=0.33IMx+1.77 (r(2)=0.682). The within-batch precision (n=20) of the dried blood spot LC-MS/MS method was 7.3% and 4.7% at concentrations of 4.0 and 7.9 micro mol/L, respectively; the between-batch precision was 12.6% and 7.9% at concentrations of 5.1 and 8.0 micro mol/L, respectively. To assess whether dried blood spots are suitable as a screening test to predict plasma tHcy concentrations, arbitary cut-off levels were compared. If it is assumed that a plasma tHcy concentration of >15 micro mol/L is raised, a dried blood spot result of >6.8 micro mol/L has a sensitivity and specificity in detecting a raised plasma tHcy of 83.3% and 96.2%, respectively, and a positive and negative predictive value of 95% and 86%, respectively, with an efficiency of 90%. Use of a dried blood spot cut-off concentration of 6.2 micro mol/L for predicting high plasma tHcy concentrations (above 15 micro mol/L) has a sensitivity and specificity of 95.8% and 73.1%, respectively, positive and negative predictive values of 76% and 95%, respectively, and an efficiency of 84%. CONCLUSIONS: We have developed a precise and accurate LC-MS/MS method for measuring plasma tHcy concentrations, which uses a small volume of plasma and is suitable for routine use. A satisfactory LC-MS/MS method for the measurement of tHcy in dried blood spots was also developed; this method might be useful in routine screening for raised plasma concentrations of tHcy.
机译:背景:目前的总同型半胱氨酸(tHcy)采样存在问题,需要在15分钟内分离血浆。这项研究的目的是开发一种液相色谱-串联质谱(LC-MS / MS)方法,用于测量血浆和干血斑中的tHcy,并确定干血斑浓度是否可用于预测血浆浓度的方法:优化LC-MS / MS方法以测量血浆和干血斑中的tHcy。从心脏移植患者收集的五十份血液样本用于形成干血斑并进行血浆分析。还使用Abbott IMx(1)方法测量血浆tHcy,并将其值与使用LC-MS / MS方法在血浆和干血斑中测定的tHcy浓度进行比较。结果:血浆tHcy LC-MS / MS结果与IMx值相比较:LC-MS / MS = 1.18(IMx)-0.44(r(2)= 0.915)。血浆LC-MS / MS方法的批内精密度(n = 10)分别在14.6和37.7 micro mol / L时<2.0%。在这些浓度下,批间精度(n = 10)分别为5.0%和8.0%。发现该方法灵敏度低至1 micro mol / L,线性低至至少100 micro mol / L。干血斑LC-MS / MS结果明显低于血浆IMx值(P <0.0001):干血斑LC-MS / MS = 0.33IMx + 1.77(r(2)= 0.682)。干血点LC-MS / MS方法的批内精密度(n = 20)在浓度为4.0和7.9 micro mol / L时分别为7.3%和4.7%。浓度为5.1和8.0 micro mol / L时,批间精密度分别为12.6%和7.9%。为了评估干血斑是否适合作为预测血浆tHcy浓度的筛查测试,比较了人流截止水平。如果假定血浆tHcy浓度升高到> 15 micro mol / L,则干血斑结果> 6.8 micro mol / L分别具有检测到升高的血浆tHcy的灵敏度和特异性,分别为83.3%和96.2% ,阳性和阴性预测值分别为95%和86%,效率为90%。使用干血点截止浓度为6.2 micro mol / L预测血浆tHcy高浓度(高于15 micro mol / L)的敏感性和特异性分别为95.8%和73.1%,正,负的预测值为分别为76%和95%,效率为84%。结论:我们已经开发出一种精确,准确的LC-MS / MS方法来测量血浆tHcy浓度,该方法使用的血浆量很小,适合常规使用。还开发了一种令人满意的LC-MS / MS方法,用于测量干血斑中的tHcy。该方法可能在常规筛查升高的tHcy血浆浓度中有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号