The spatial distribution of illuminance and the electric consumption of artificial lighting system is one of the main problems related to broiler production. Therefore, the aim of this study was to evaluate the spatial distribution of luminance level and energy efficiency of different lighting systems for broiler houses. Six types of lamps were tested in two different configurations to find the minimum illuminance of 20 and 5 lux. The tested lamps were incandescent (IL) 100 W, compact fluorescent (CFL) 34 W, mixed (ML) 160 W, sodium vapor (SVL) 70 W, T8 fluorescent tube (T8 FTL) 40 W and T5 fluorescent tube (T5 FTL) 28 W. The first four were evaluated with and without reflective light fixture and the latter two without light fixture. It was observed that the tested system with light fixtures negatively affected the spatial distribution of illuminance inside the house. The systems composed by IL and ML without light fixture led to better results in meeting the minimum illuminance of 20 lux and 5 lux, respectively. T5 FTL presented the lowest energy demand.
机译:照度的空间分布和人工照明系统的耗电量是肉鸡生产的主要问题之一。因此,本研究的目的是评估肉鸡舍不同照明系统的亮度水平和能源效率的空间分布。在两种不同的配置下测试了六种类型的灯,以找到 20 和 5 勒克斯的最小照度。测试灯为白炽灯 (IL) 100 W、紧凑型荧光灯 (CFL) 34 W、混合灯 (ML) 160 W、钠蒸气灯管 (SVL) 70 W、T8 荧光灯管 (T8 FTL) 40 W 和 T5 荧光灯管 (T5 FTL) 28 W。前四个评估了有和没有反射灯具,后两个没有灯具。据观察,带有灯具的测试系统对房屋内照度的空间分布产生了负面影响。由IL和ML组成的系统在没有灯具的情况下分别在满足20勒克斯和5勒克斯的最小照度方面取得了更好的结果。T5 FTL 的能源需求最低。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号