Paper presents a technique for performance of UV sterilizer for room air bacteria. Patterns of decay of room air bacteria concentration during sterilization and build-up there after as a function of time is studied. Decay process seems to follow exponential pattern. Half-lives during decay are estimated. For single sterilizer unit with a dose of 16 W the decay half-life is around 8.6 min. For the dose of 32 W (2 sterilizers), half-life is estimated to be 6.18 min. The removal rates of room air bacteria due to sterilizer are compared with the natural decay of aerosols at steady state. The importance of decay half-life in the assessment has been stated. The bacteria concentration buildup process after putting off the sterilizers seems to be sigmoidalin nature. The buildup half-life is estimated to be around 53 min for present experimental conditions.
机译:论文提出了一种用于室内空气细菌的紫外线消毒器性能的技术。研究了灭菌过程中室内空气细菌浓度的衰减模式,以及之后随时间的积累。衰减过程似乎遵循指数模式。估计衰变期间的半衰期。对于剂量为16 W的单个消毒器单元,衰减半衰期约为8.6分钟。对于32 W的剂量(2个消毒器),半衰期估计为6.18分钟。将灭菌器对室内空气细菌的去除率与稳定状态下气溶胶的自然衰减进行了比较。已经阐明了衰减半衰期在评估中的重要性。推迟使用消毒器后细菌浓度的增加过程似乎是乙状结肠素。对于目前的实验条件,累积的半衰期估计为53分钟左右。