Cadmium 1-(2-pyridylazo)-2-naphthol complex is quantitatively adsorbed on microcrystalline naphthalene in the pH range 8.0-10.5. It can also be alternatively adsorbed on [1-(2-pyridylazo)-2-naphthol]-naphthalene adsorbent packed in a column at a flow rate of 1-2 mL/min and the metal determined by flame atomic absorption spectrometrically by measuring the absorbance at 228.8 nm against a reagent blank. About 0.05 #mu#g of cadmium can be concentrated in a column from 450 mL of aqueous sample, where its concentration is as low as 0.11 ng/mL. The detection limit is 44 pg/mL for cadmium at the minimum instrumental settings. The linearity is maintained in the concentration range 0.11 ng/mL to 0.4 #mu#g/mL cadmium in aqueous solution or 0.01 to 1.6 #mu#g/mL cadmium in the final DMF solution with a correlation factor of 0.9995. Eight replicate determinations of 0.3 #mu#g/mL of cadmium in final DMF solution give a mean absorbance of 0.150 with a relative standard deviation of 1.6%. The sensitivity for 1% absorption is 8.8 ng/mL in final DMF solution. The interference of a large number of anions and cations on the determination of cadmium after the preconcentration step have been studied and the optimized conditions developed utilized for its trace determination in various alloys and biological samples. The method may also be used for the determination of cadmium in various environmental samples.
机译:1-(2-吡啶基偶氮)-2-萘酚镉络合物定量吸附在pH值为8.0-10.5的微晶萘上。也可以将其以1-2 mL / min的流速吸附在装在色谱柱中的[1-(2-吡啶基偶氮)-2-萘酚]-萘吸附剂上,并通过火焰原子吸收光谱法测定相对于空白试剂在228.8 nm处的吸光度。可以从450毫升含水样品中的柱子中浓缩约0.05#μ#g镉,其浓度低至0.11 ng / mL。在最低仪器设置下,镉的检出限为44 pg / mL。线性度在水溶液中的镉浓度范围为0.11 ng / mL至0.4#mu#g / mL镉或最终DMF溶液中的镉浓度为0.01至1.6#mu#g / mL线性,相关系数为0.9995。八次重复测定最终DMF溶液中的镉为0.3#mu#g / mL,得到的平均吸光度为0.150,相对标准偏差为1.6%。在最终DMF溶液中,1%吸收的灵敏度为8.8 ng / mL。研究了预浓缩步骤后大量阴离子和阳离子对镉的测定的干扰,并开发了用于在各种合金和生物样品中进行痕量测定的优化条件。该方法还可用于测定各种环境样品中的镉。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号