Investigating changes in corrosion mechanism induced by laser welding galvanised steel specimens using scanning vibrating electrode technique

机译:利用扫描振动电极技术研究镀锌钢板激光焊接引起的腐蚀机理变化

获取原文
获取原文并翻译 | 示例
           

摘要

A novel three-dimensional scanning vibrating electrode technique (3D SVET) apparatus is described, which uses a bifunctional probe to record topographical and current density data. This apparatus is used to investigate the localised corrosion occurring on 2 cm~2 exposed areas of fiat specimens of electroplated zinc and galvannealed (Zn-Fe alloy coated) 1.2 mm sheet steel and specimens of the same substrates laser welded together freely corroding in near neutral, aerated, aqueous chloride electrolyte. On fiat galvannealed (IZ) specimens anodic events are highly localised and occur at random over the exposed specimen surface during a 24 h immersion period. This reflects the progressive dezincification of zinc rich areas of the iron zinc intermetallic coating. By contrast on flat electroplated zinc (EZ) specimens anodic activity is localised but corrosion initiates at a single anodic centre, eventually spreading out to form a scar on the metallic surface. This concentration of anodic activity on the specimen leads to greater dezincification than for the IZ coating. The SVET data was used to provide an estimate of the total zinc loss from the 2 cm~2 exposed area on the coupons of 544 mu g for EZ and 236 mu g for IZ respectively. The close physical proximity of anodic and cathodic events in the latter substrate is believed to lead to greater zinc (hydr)oxide formation and hence lower measured zinc loss. Laser welded specimens were prepared by joining IZ to IZ and IZ to EZ canted 1.2 mm steel panels. A 2 cm~2 exposed area was investigated using SVET with ca. 1 cm~2 exposed either side of the weld. The joining of IZ specimens together using a laser weld changes the localisation of anodic activity in neutral aerated sodium chloride solution dramatically. In this instance focal anodes initially concentrate next to the weld area in a zone enriched in zinc (and depleted in iron) as a result of the welding process. This localisation of anodic and cathodic activity next to the weld reduces the anodic damage on the IZ remote to the heat affected zone. When specimens of EZ and IZ are laser welded together all anodic activity becomes focussed on the EZ specimens with a total zinc loss over 24 h from the 1 cm~2 exposed area measured as 489 mu g, very close to that of the zinc loss from the EZ specimen (2 cm~2) alone. By contrast there is no measurable zinc loss from the IZ portion specimen under these conditions. The increase in zinc loss per unit area from the EZ reflects the additional cathodic area provided by the connected IZ coupon and bimetallic coupling of the metallic coatings.
机译:描述了一种新颖的三维扫描振动电极技术(3D SVET)设备,该设备使用双功能探针记录地形和电流密度数据。该设备用于研究镀锌和镀锌(镀锌-铁合金)1.2 mm钢板的平整试样和激光焊接在一起的同一基板的试样在2 cm〜2暴露区域中发生的局部腐蚀,这些试样在近中性的环境中自由腐蚀,充气,氯化物水溶液电解质。在法定镀锌(IZ)样品上,阳极事件高度局限,并且在浸入的24小时内随机发生在裸露样品表面上。这反映出铁锌金属间化合物涂层的富锌区域逐渐脱锌。相比之下,在平坦的电镀锌(EZ)标本上,阳极活性是局部的,但腐蚀在单个阳极中心开始,最终扩展到金属表面上形成疤痕。与IZ涂层相比,样品上的这种阳极活性集中导致更大的脱锌作用。 SVET数据用于估算从试样上2 cm〜2暴露区域的总锌损失,其中EZ对于544μg,IZ在236μg。据信在后者的基体中阳极和阴极事件的紧密物理接近会导致形成更大的(氢氧化)氧化锌,从而降低测得的锌损失。通过将IZ连接到IZ和将IZ连接到EZ倾斜的1.2 mm钢板来制备激光焊接样品。使用SVET研究了2 cm〜2的裸露面积,约为。 1 cm〜2暴露在焊缝的任何一侧。使用激光焊接将IZ标本连接在一起会极大地改变中性充气氯化钠溶液中阳极活性的定位。在这种情况下,由于焊接过程的缘故,焦点阳极最初集中在焊接区域附近的一个富含锌(而贫铁)的区域中。靠近焊缝的阳极和阴极活性的这种定位降低了远离热影响区的IZ上的阳极损伤。当将EZ和IZ样品激光焊接在一起时,所有阳极活性都集中在EZ样品上,从1 cm〜2的暴露区域起,在24小时内锌的总损失为489μg,非常接近于单独的EZ标本(2 cm〜2)。相反,在这些条件下,IZ部分样品没有可测量的锌损失。 EZ的每单位面积锌损失的增加反映了由相连的IZ试样和金属涂层的双金属耦合提供的额外阴极面积。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号