The possible association among bone density values, resonance frequency measurements, tactile sense, and histomorphometric evaluations of dental implant osteotomy sites: a preliminary study.

机译:牙种植体截骨部位的骨密度值,共振频率测量,触觉和组织形态计量学评估之间的可能关联:初步研究。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: The aim of the clinical preliminary trial was to determine the possible relationship among radiologic bone density, primary implant stability, and tactile sense measurements, and to clarify their possible association with histological measurements at endosseous implant osteotomy sites. MATERIALS: Eleven mandibular and 12 maxillary sites of 10 patients were included. Computerized tomography was used for preoperative evaluation of the jaw-bone for each dental implant site, and bone densities were recorded in Hounsfield units (HU). Implant stability quotients (ISQ) were determined with the Osstell Mentor device. Bone core biopsies were taken from the implant osteotomy sites, where the tactile sense of the practitioner while placing the implants was also recorded. RESULTS: The average radiologic bone density, primary implant stability, and trabecular bone volume (TBV) values were 554.87 HU, 72 ISQ, and 41% for 23 dental implants, respectively. Maxillary sites presented a statistically significant decrease HU values compared with sites in the mandible. The mean TBV in mandibles presented a trend of increase compared to maxillary sites. A significant correlation was noted between ISQ values and tactile sense for male patients, where HU values demonstrated significant correlations among ISQ values, TBV measurements, and tactile sense evaluations in women. CONCLUSIONS: The results of this study demonstrated that computerized tomography measurements in terms of HU evaluations may be a helpful technique for predicting primary stability of the implant and bone quality. Further studies should be performed to understand the relationship between clinical assessments and histological evaluations in implant osteotomy sites in humans.
机译:目的:临床初步试验的目的是确定放射学骨密度,初级植入物稳定性和触觉测量之间的可能关系,并阐明它们与骨内植入物截骨部位的组织学测量之间的可能联系。材料:包括10例患者的11个下颌骨和12个上颌骨部位。使用计算机断层扫描术对每个种植牙部位的颌骨进行术前评估,并以Hounsfield单位(HU)记录骨密度。使用Osstell Mentor设备确定植入物稳定性商(ISQ)。骨芯活检取自植入物截骨部位,在此处还记录了从业人员放置植入物时的触觉。结果:23颗牙种植体的平均放射学骨密度,主种植体稳定性和小梁骨体积(TBV)值分别为554.87 HU,72 ISQ和41%。与下颌骨部位相比,上颌骨部位的HU值在统计学上显着降低。下颌骨的平均TBV与上颌骨部位相比呈增加趋势。男性患者的ISQ值与触觉之间存在显着相关性,其中HU值表明ISQ值,TBV测量值和女性触觉评估之间存在显着相关性。结论:这项研究的结果表明,计算机断层摄影术在HU评估方面的测量可能是预测植入物的主要稳定性和骨质量的有用技术。应该进行进一步的研究,以了解人体植入物截骨部位的临床评估与组织学评估之间的关系。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号