摘要

Objectives:SLAffinity is the hybrid topography consisting of micropits and nanoporous TiO2 layers through electrochemical oxidation to mimic the natural bony environment. The aim of this study was to examine the rate of osseointegration in animal models and to further investigate the stability for implants with SLAffinity-treated surface in the clinical trial.Materials and Methods:Implants were installed in the mandibular canine-premolar area of 12 miniature pigs. Each pig received 2 implants with the same shapes but with different chemical surfaces. In the clinical trial, 25 patients were included. Each patient received 1 SLAffinity-treated implant on the posterior area of either arch. Resonance frequency analysis and computed tomography were assessed weekly over the first 12 weeks after implant placement.Results:The results found that surface treatment did affect the bone-to-implant contact (BIC) significantly. Comparison of BIC at 3 weeks in animal study showed that the SLAffinity-treated implants presented significantly higher values than machine surface implants. SLAffinity-treated implants also proved clinically successful through 12 months, ready for prosthodontic restoration.Conclusion:The effect of SLAffinity treatments enhanced osseointegration significantly, especially at early stages of bone healing. Clinical trial finding, furthermore, ensured that the SLAffinity treatment was a reliable surface modification alternative.
机译:目的:SLAffinity是由微坑和纳米多孔TiO2层通过电化学氧化模拟自然骨环境组成的混合形貌。这项研究的目的是检查动物模型中的骨整合率,并在临床试验中进一步研究经SLAffinity处理的表面的植入物的稳定性。材料和方法:在下颌犬前磨牙区中的12个微型模型中安装了放大器猪。每头猪接受2个形状相同但化学表面不同的植入物。在临床试验中,包括25名患者。每个患者在任一弓的后部区域接受1个经SLAffinity处理的植入物。植入后头12周每周进行一次共振频率分析和计算机断层扫描。结果:结果发现,表面处理确实显着影响了骨与植入物之间的接触(BIC)。在动物研究中比较了3周时的BIC,结果表明,经SLAffinity处理的植入物的价值明显高于机器表面植入物。经SLAffinity处理的植入物在12个月内也证明了临床成功,可以进行修复修复。结论:SLAffinity治疗的效果显着增强了骨整合,尤其是在骨愈合的早期。此外,临床试验发现确保SLAffinity处理是可靠的表面改性替代方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号