The negative interference by bilirubin in serum creatinine estimation by Jaffe's kinetic method is well known. Several approaches have been suggested to overcome this interference. In this article three different creatinine kits (Jaffe's kinetic method) have been tested for bilirubin interference and its rectification using two simple approaches. The performance of three kits (A, B and C) supplied by three different manufacturers was tested using IQC and EQAS sera and pooled serum with added bilirubin. To overcome the bilirubin interference two approaches viz. NaOH preincubation and TCA precipitation were used. Bilirubin did interfere in creatinine estimation after a certain level (2.3 mg/dl). However, both NaOH preincubation and TCA precipitation approach rectified this interference. The performance of kit A was better than kit B and C. All the three kits showed bilirubin interference upon increasing the bilirubin concentration but kit A performed better than kit B and C. However, NaOH incubation and TCA precipitation methods overcame this interference to a great extent.
机译:胆红素对通过Jaffe动力学法评估血清肌酐的负面影响是众所周知的。已经提出了几种方法来克服这种干扰。在本文中,已经使用两种简单方法测试了三种不同的肌酐试剂盒(Jaffe动力学方法)对胆红素的干扰及其矫正作用。使用IQC和EQAS血清以及添加了胆红素的混合血清测试了三个不同制造商提供的三个试剂盒(A,B和C)的性能。为了克服胆红素干扰,有两种方法。使用NaOH预温育和TCA沉淀。一定水平(2.3 mg / dl)后胆红素确实会干扰肌酐的估计。但是,NaOH预孵育和TCA沉淀方法都可以纠正这种干扰。试剂盒A的性能优于试剂盒B和C。这三种试剂盒在增加胆红素浓度后均显示出胆红素干扰,但试剂盒A的性能优于试剂盒B和C。但是,NaOH孵育和TCA沉淀方法大大克服了这种干扰。程度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号