首页> 外文期刊>Automation >Sectional drives give more from less: The use of sectional drives sharing a common DC bus has reduced the likelihood of overloads on centrifuges used by British Sugar
【24h】

Sectional drives give more from less: The use of sectional drives sharing a common DC bus has reduced the likelihood of overloads on centrifuges used by British Sugar

机译:分段驱动器提供的收益更少:使用共享直流母线的分段驱动器减少了英国制糖公司使用的离心机过载的可能性

获取原文
获取原文并翻译 | 示例
       

摘要

At British Sugar's Newark factory, MultiDrives from ABB are being [used to drive three centrifuge inits, which spin off sugar crystals from solution. Using a DC bus system, all the inverter sections for each centrifuge are supplied from the same common DC bus, which itself is supplied from the common regenerative rectifier. Sectional drives sharing a common DC bus can offer a cost-effective option in applications at larger powers, from about, 100 kW, DC bus drives use common components to control and supply power to the inverter sections of AC drives, reducing costs. A single rectifier can supply several inverter sections from a common DC bus, rather than using one rectifier per inverter as is the case with standalone units. Up to 25% less space is needed owing to the smaller components count.
机译:在英国糖业的纽瓦克工厂,ABB的MultiDrives被用于驱动三个离心机,这些离心机从溶液中分离出糖晶体。使用DC总线系统,每个离心机的所有逆变器部分均由同一条公共DC总线供电,而该公共DC总线本身是由公共再生整流器供电的。共享公共直流母线的分段驱动器可以在大功率应用中提供经济高效的选择,功率从大约100 kW开始,直流母线驱动器使用通用组件控制交流驱动器的逆变器部分并为其供电,从而降低了成本。单个整流器可以从公共DC总线提供多个逆变器部分,而不是像独立单元那样每个逆变器使用一个整流器。由于组件数量较少,因此所需空间最多减少25%。