首页> 外文期刊>Journal of Constructional Steel Research >Screwed connections in built-up cold-formed steel members at ambient and elevated temperatures
【24h】

Screwed connections in built-up cold-formed steel members at ambient and elevated temperatures

机译:Screwed connections in built-up cold-formed steel members at ambient and elevated temperatures

获取原文
获取原文并翻译 | 示例
           

摘要

Screwed connections are commonly used in fabricating built-up cold-formed steel (CFS) members. However, the knowledge and understanding of their behaviour and design are limited. This research study investigated the shear behaviour and capacity of the screwed connections used in built-up CFS members. It included a series of shear tests of screwed connections between two single channel members as used in built-up back-to-back CFS members, failing by tilting and bearing. Tests were conducted at both ambient and elevated temperatures. Using the results from these tests and available literature, this study has shown that the design equations for the tilting and bearing capacity of screwed connections in the current CFS design standards are reliable for the screwed connections in built-up CFS members at ambient temperature. It has then shown that the same design equations can be used to predict the tilting and bearing capacity of these screwed connections at elevated temperatures if they are used in combination with the proposed reduction factor equations for elevated temperature capacities. Details of this research study, its results and findings are presented in this paper.