首页> 外文期刊>Atmospheric chemistry and physics >Validation of ozone monitoring instrument (OMI) ozone profiles and stratospheric ozone columns with microwave limb sounder (MLS) measurements
【24h】

Validation of ozone monitoring instrument (OMI) ozone profiles and stratospheric ozone columns with microwave limb sounder (MLS) measurements

机译:通过微波肢体测深仪(MLS)测量验证臭氧监测仪(OMI)臭氧剖面和平流层臭氧柱

获取原文
获取原文并翻译 | 示例
       

摘要

We validate OMI ozone profiles between 0.22-215 hPa and stratospheric ozone columns down to 215 hPa (SOC215) against v2.2 MLS data from 2006. The validation demonstrates convincingly that SOC can be derived accurately from OMI data alone, with errors comparable to or smaller than those from current MLS retrievals, and it demonstrates implicitly that tropospheric ozone column can be retrieved accurately from OMI or similar nadir-viewing ultraviolet measurements alone. The global mean biases are within 2.5% above 100 hPa and 5-10% below 100 hPa; the standard deviations of the differences (1?) are 3.5-5% between 1-50 hPa, 6-9% above 1 hPa and 8-15% below 50 hPa. OMI shows some latitude and solar zenith angle dependent biases, but the mean biases are mostly within 5% and the standard deviations are mostly within 2-5% except for low altitudes and high latitudes. The excellent agreement with MLS data shows that OMI retrievals can be used to augment the validation of MLS and other stratospheric ozone measurements made with even higher vertical resolution than that for OMI. OMI SOC215 shows a small bias of 0.6% with a standard deviation of 2.8%. When compared as a function of latitude and solar zenith angle, the mean biases are within 2% and the standard deviations range from 2.1 to 3.4%. Assuming 2% precision for MLS SOC215, we deduce that the upper limits of random-noise and smoothing errors for OMI SOC215 range from 0.6% in the southern tropics to 2.8% at northern middle latitudes.
机译:我们针对2006年以来的v2.2 MLS数据验证了0.22-215 hPa和低至215 hPa(SOC215)的平流层臭氧柱之间的OMI臭氧剖面。该验证令人信服地表明,仅凭OMI数据即可准确得出SOC,其误差可与或它比目前的MLS检索结果要小,并且隐含地证明对流层臭氧柱可以仅从OMI或类似的最低观测紫外线测量值中精确地检索出来。全球平均偏差在100 hPa以上2.5%以内,在100 hPa以下5-10%。在1-50 hPa之间,差异(1?)的标准偏差为3.5-5%,在1 hPa以上为6-9%,在50 hPa以下为8-15%。 OMI显示出一些与纬度和太阳天顶角有关的偏差,但除低海拔和高纬度外,平均偏差大部分在5%以内,标准偏差大部分在2%至5%之内。与MLS数据的极好的一致性表明,OMI检索可用于增强MLS和其他平流层臭氧测量的验证性,该测量的垂直分辨率甚至高于OMI。 OMI SOC215显示出0.6%的小偏差,标准偏差为2.8%。当将其作为纬度和太阳天顶角的函数进行比较时,平均偏差在2%以内,标准偏差范围为2.1至3.4%。假设MLS SOC215的精度为2%,我们推断OMI SOC215的随机噪声和平滑误差的上限范围从南热带的0.6%到北中纬度的2.8%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号