...
首页> 外文期刊>Medical Physics >Assessment of pulmonary morphometry using hyperpolarized 129Xe diffusion‐weighted MRI with variable‐sampling‐ratio compressed sensing patterns
【24h】

Assessment of pulmonary morphometry using hyperpolarized 129Xe diffusion‐weighted MRI with variable‐sampling‐ratio compressed sensing patterns

机译:Assessment of pulmonary morphometry using hyperpolarized 129Xe diffusion‐weighted MRI with variable‐sampling‐ratio compressed sensing patterns

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Abstract Background Hyperpolarized (HP) 129Xe multiple b‐values diffusion‐weighted magnetic resonance imaging (DW‐MRI) has been widely used for quantifying pulmonary microstructural morphometry. However, the technique requires long acquisition times, making it hard to apply in patients with severe pulmonary diseases, who cannot sustain long breath holds. Purpose To develop and evaluate the technique of variable‐sampling‐ratio compressed sensing (VCS) patterns for accelerating HP 129Xe multiple b‐values DW‐MRI in humans. Methods Optimal variable sampling ratios and corresponding k‐space undersampling patterns for each b‐value were obtained by retrospective simulations based on the fully sampled (FS) DW‐MRI dataset acquired from six young healthy volunteers. Then, the FS datasets were retrospectively undersampled using both VCS patterns and conventional compressed sensing (CS) pattern with a similar average acceleration factor. The quality of reconstructed images with retrospective VCS (rVCS) and CS (rCS) datasets were quantified using mean absolute error (MAE) and structural similarity (SSIM). Pulmonary morphometric parameters were also evaluated between rVCS and FS datasets. In addition, prospective VCS multiple b‐values 129Xe DW‐MRI datasets were acquired from 14 cigarette smokers and 13 age‐matched healthy volunteers. The differences of lung morphological parameters obtained with the proposed method were compared between the groups using independent samples t‐test. Pearson correlation coefficient was also utilized for evaluating the correlation of the pulmonary physiological parameters obtained with VCS DW‐MRI and pulmonary function tests. Results Lower MAE and higher SSIM values were found in the reconstructed images with rVCS measurement when compared to those using conventional rCS measurement. The details and quality of the images obtained with rVCS and FS measurements were found to be comparable. The mean values of the morphological parameters derived from rVCS and FS datasets showed no significant differences (p?>?0.05), and the mean differences of measured acinar duct radius, mean linear intercept, surface‐to‐volume ratio, and apparent diffusion coefficient with cylinder model were ?0.87, ?2.42, 2.04, and ?0.50, respectively. By using the VCS technique, significant differences were delineated between the pulmonary morphometric parameters of healthy volunteers and cigarette smokers (p?

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号